…nd router use build_netclasses hardcoded 0.2 mm for the inferred Power class on every board but RP2350, while the project file wrote it at the manufacturer minimum the router honours. KiCad checked 0.2 mm, so legally routed copper next to GND and 3V3 pads was reported.
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
What type of PR is this?
This is a bug fix
What does this do?
build_netclasseswrites the inferredPowerclass atDEFAULT_CLASS_CLEARANCE_MM(0.127), matchingDefaultand the.kicad_pro.Which issue(s) does this PR fix/relate to?
Resolves #287
Have you included tests for your changes?
Yes,
netclass_is_top_level_outside_setupassertsDefaultandPowerboth emit 0.127 and none 0.2.Did you document any new/modified features?
No, behaviour only; a comment on