34 changes: 34 additions & 0 deletions .changeset/loadmodel-outlier-lockout.md
Original file line number Diff line number Diff line change
@@ -0,0 +1,34 @@
---
"ftw": patch
---

Load model: replace the MAE-band outlier filter with a physical ceiling
taken from the main fuse. The band rejected the upper half of the real
load distribution, and could lock the model out of a level it had not seen
before, permanently.

A rejected sample updates neither `MAE` nor `Samples`, so the band
`max(MAE × 10, 200)` never grew in response to being persistently wrong.
Measured on a clean model: an hour at 400 W left MAE at 57 W and the band
at 570 W; a following week at 5 kW was rejected in full, 100% of samples,
and the prediction never moved off 1794 W.

The band was the wrong instrument, not merely mistuned. Household load is
multimodal — a few hundred watts of baseline, then 11 kW when the sauna,
oven and car overlap — and nothing about a residual's size separates
"unusual but real" from "wrong". A band fitted to the quiet hours always
excludes the busy ones. Short-term measurement noise is already handled a
layer down, by the Kalman filter in telemetry whose smoothed output this
model reads, so the second filter was both harmful and redundant.

What remains is the rejection physics licenses: a house cannot draw more
than its main fuse passes. The ceiling is `fuse capacity × 1.25`, passed in
from configuration and never derived from what the model has learned, so it
holds from the first sample and cannot be talked down by a model that has
mislearned. With no fuse configured the check disables itself rather than
inventing a limit.

A sustained shift to a new load level is now learned directly. A one-minute
spike still trains — it is real consumption — and the bucket EMA damps it
to a tenth of the gap, which is what keeps an hour from being defined by
its loudest minute.
10 changes: 9 additions & 1 deletion go/cmd/ftw/main.go
Original file line number Diff line number Diff line change
Expand Up @@ -1030,7 +1030,15 @@ func main() {
if loadPeakW <= 0 {
loadPeakW = 5000
}
loadSvc = loadmodel.NewService(st, tel, cfg.SiteMeterDriver(), loadPeakW)
// Training ceiling: the main fuse is the one hard limit on what a house
// can actually draw, so a sample above it is a measurement fault rather
// than an unusual hour. Passed separately from loadPeakW — that one is a
// tunable proxy for "typical peak", this one is physics, and deriving
// the second from the first would silently move a safety bound whenever
// somebody retuned the proxy. Zero when no fuse is configured, which
// disables the check rather than inventing a limit.
loadMaxPlausibleW := cfg.Fuse.MaxPowerW() * loadmodel.PlausibleLoadHeadroom
loadSvc = loadmodel.NewService(st, tel, cfg.SiteMeterDriver(), loadPeakW, loadMaxPlausibleW)
// SeedHeatingCoef — operator config is a cold-start prior. Once the
// load model has accumulated samples in production, its
// telemetry-fit HeatingW_per_degC survives restart and the config
Expand Down
4 changes: 2 additions & 2 deletions go/internal/api/api_loadmodel_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -12,7 +12,7 @@ import (
)

func TestHandleLoadModelProfileSwitch(t *testing.T) {
lm := loadmodel.NewService(nil, telemetry.NewStore(), "site", 4000)
lm := loadmodel.NewService(nil, telemetry.NewStore(), "site", 4000, 17250)
srv := New(&Deps{LoadModel: lm})

req := httptest.NewRequest(http.MethodPost, "/api/loadmodel/profile", strings.NewReader(`{"profile":"away"}`))
Expand Down Expand Up @@ -51,7 +51,7 @@ func TestHandleLoadModelProfileSwitch(t *testing.T) {
}

func TestHandleLoadModelProfileRejectsUnknown(t *testing.T) {
lm := loadmodel.NewService(nil, telemetry.NewStore(), "site", 4000)
lm := loadmodel.NewService(nil, telemetry.NewStore(), "site", 4000, 17250)
srv := New(&Deps{LoadModel: lm})

req := httptest.NewRequest(http.MethodPost, "/api/loadmodel/profile", strings.NewReader(`{"profile":"vacation"}`))
Expand Down
2 changes: 1 addition & 1 deletion go/internal/calendar/e2e_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -24,7 +24,7 @@ func TestEndToEndRealCollaborators(t *testing.T) {
}
defer st.Close()

loadSvc := loadmodel.NewService(st, nil, "", 5000)
loadSvc := loadmodel.NewService(st, nil, "", 5000, 17250)
lpMgr := loadpoint.NewManager()
lpMgr.Load([]loadpoint.Config{{ID: "garage", VehicleCapacityWh: 60000}})

Expand Down
44 changes: 36 additions & 8 deletions go/internal/loadmodel/model.go
Original file line number Diff line number Diff line change
Expand Up @@ -63,6 +63,13 @@ const HeatingMinDeltaT = 3.0
// home. Clamp prevents one anomalous sample from blowing up the fit.
const HeatingCoefMaxW = 1500.0

// PlausibleLoadHeadroom multiplies the main fuse capacity to get the
// point past which a reading must be a fault. Above 1.0 because a fuse
// tolerates brief overload and a meter can overshoot a step; well below
// anything a real house sustains, so a genuine 11 kW hour on a 25 A
// service is nowhere near it.
const PlausibleLoadHeadroom = 1.25

// Profile selects which learned occupancy profile is used for training
// and prediction.
type Profile string
Expand Down Expand Up @@ -104,6 +111,13 @@ type Model struct {
MAE float64 `json:"mae"`
Alpha float64 `json:"alpha"` // EMA coefficient for bucket updates
PriorScale float64 `json:"prior_scale,omitempty"`

// MaxPlausibleW is the physical ceiling a sample must fall under to be
// trained on: main fuse capacity plus headroom. Derived from configured
// hardware and never from what the model has learned, so it cannot be
// talked down by a model that has mislearned. 0 disables the check —
// the state a site with no fuse configuration is in.
MaxPlausibleW float64 `json:"max_plausible_w,omitempty"`
}

// typicalPrior returns an approximate W load for a given hour-of-week
Expand Down Expand Up @@ -240,6 +254,28 @@ func (m *Model) Update(t time.Time, actualLoadW, tempC float64) (updated bool) {
if actualLoadW < 0 {
return false
}

// Physical bound — the only sample filter this model needs, and the
// first thing it does. A house cannot draw more than its main fuse
// passes, so a reading above it is a fault and must touch nothing:
// not the buckets, not MAE, and not the heating coefficient. Running
// it after the heating fit let one cold-weather meter fault move
// HeatingW_per_degC while Update still reported no update applied,
// and repeated faults could walk the coefficient to its ceiling.
//
// A household's real load is strongly multimodal: a few hundred watts
// of baseline for most of the day, then 11 kW when the sauna, oven and
// car overlap. Both are true readings. Nothing about a residual's size
// distinguishes "unusual but real" from "wrong", which is why this is
// the only rejection left — see the git history for the MAE band that
// used to sit below, and what it cost.
//
// Short-term noise is handled a layer down: telemetry runs a Kalman
// filter per signal and this model reads the smoothed values.
if m.MaxPlausibleW > 0 && actualLoadW > m.MaxPlausibleW {
return false
}

idx := HourOfWeek(t)
b := &m.Bucket[idx]
predicted := m.Predict(t, tempC)
Expand Down Expand Up @@ -273,14 +309,6 @@ func (m *Model) Update(t time.Time, actualLoadW, tempC float64) (updated bool) {
}
}

// Outlier filter: once we have some history, reject 10× MAE residuals.
if m.Samples > 50 {
band := math.Max(m.MAE*10, 200)
if math.Abs(err) > band {
return false
}
}

// Bucket update: exact running mean for the first 10 samples (crisp
// early convergence), EMA after (smooth drift as the home evolves).
// Subtract the current heating-gain estimate so the bucket learns
Expand Down
174 changes: 174 additions & 0 deletions go/internal/loadmodel/model_test.go
Original file line number Diff line number Diff line change
Expand Up @@ -125,8 +125,15 @@ func TestRejectsNegativeLoad(t *testing.T) {
}
}

// Outlier rejection is now anchored to the site's fuse rather than to a
// band fitted from the model's own history. The behaviour this test
// protects is unchanged — a 50 kW reading must not move the bucket — but
// it needs the physical ceiling set, which production wires from the fuse
// configuration. The band version of this check also rejected genuine
// household peaks; see TestFullHouseholdRangeIsTrained.
func TestRejectsOutliers(t *testing.T) {
m := NewModel(4000)
m.MaxPlausibleW = 17250
start := time.Date(2026, 1, 5, 12, 0, 0, 0, time.UTC)
for i := 0; i < 200; i++ {
m.Update(start.Add(time.Duration(i)*time.Minute), 1500, HeatingReferenceC)
Expand Down Expand Up @@ -329,3 +336,170 @@ func TestHeatingFitWaitsForBucketTrust(t *testing.T) {
t.Errorf("untrusted bucket must not drive heating fit, coef = %.0f", m.HeatingW_per_degC)
}
}

// The MAE-band outlier filter used to reject the real house permanently.
// A rejected sample updates neither MAE nor Samples, so the band could
// never grow in response to being persistently wrong: one quiet hour at
// 400 W produced a 570 W band, after which a week at 5 kW was rejected in
// full and the prediction never moved off 1794 W.
//
// The band was the wrong instrument. Household load is multimodal — a few
// hundred watts of baseline, then 11 kW when the sauna, oven and car
// overlap — and nothing about a residual's size separates "unusual but
// real" from "wrong". Short-term noise is already handled by the Kalman
// filter in telemetry, one layer down.
func TestSustainedLevelShiftIsLearned(t *testing.T) {
m := NewModel(10000)
m.MaxPlausibleW = 17000
start := time.Date(2026, 7, 1, 2, 0, 0, 0, time.UTC)

// Two quiet days — under the old filter this is what armed a band so
// narrow that the house could never be learned.
n := 0
for ; n < 2*24*60; n++ {
m.Update(start.Add(time.Duration(n)*time.Minute), 400, HeatingReferenceC)
}

trainedFrom := n
for i := 0; i < 3*24*60; i++ {
m.Update(start.Add(time.Duration(n)*time.Minute), 3000, HeatingReferenceC)
n++
}

for i := trainedFrom; i < n; i += 60 {
got := m.Predict(start.Add(time.Duration(i)*time.Minute), HeatingReferenceC)
if math.Abs(got-3000) > 300 {
t.Fatalf("bucket at minute %d predicts %.0f W, want ~3000 W", i, got)
}
}
}

// A house that goes from near-idle to 11 kW is doing something ordinary,
// not reporting a fault. That whole range has to reach the model.
func TestFullHouseholdRangeIsTrained(t *testing.T) {
m := NewModel(8000)
m.MaxPlausibleW = 17250 // 25 A × 3 × 230 V
start := time.Date(2026, 7, 1, 3, 0, 0, 0, time.UTC)

for i, load := range []float64{200, 11000, 300, 9500, 250, 11000} {
if !m.Update(start.Add(time.Duration(i)*time.Minute), load, HeatingReferenceC) {
t.Errorf("%.0f W is a normal household reading and was rejected", load)
}
}
if m.Samples != 6 {
t.Errorf("samples = %d, want 6", m.Samples)
}
}

// Rejection is licensed by physics alone: a house cannot draw more than
// its main fuse passes. Because the bound comes from configured hardware
// rather than from what the model has learned, it holds from the first
// sample and a mislearned model cannot talk it down.
func TestImplausibleLoadRejected(t *testing.T) {
m := NewModel(4000)
m.MaxPlausibleW = 11000 * PlausibleLoadHeadroom // 16 A service
t0 := time.Date(2026, 1, 5, 12, 0, 0, 0, time.UTC)

if m.Update(t0, 50000, HeatingReferenceC) {
t.Error("50 kW past a 16 A service should never be accepted")
}
if m.Samples != 0 {
t.Errorf("rejected sample must not count, samples = %d", m.Samples)
}
// Right at the service limit is high but real — a fuse passes its
// rating, so this has to train.
if !m.Update(t0, 11000, HeatingReferenceC) {
t.Error("a load at the service limit should be accepted")
}
}

// No fuse configured means no defensible ceiling, so the check disables
// itself rather than inventing one.
func TestNoFuseConfiguredTrainsEverything(t *testing.T) {
m := NewModel(4000)
t0 := time.Date(2026, 1, 5, 12, 0, 0, 0, time.UTC)
if !m.Update(t0, 50000, HeatingReferenceC) {
t.Error("with MaxPlausibleW unset the model should not reject")
}
}

// A one-minute spike is real and trains, but the bucket EMA is what keeps
// it from dominating the hour — no separate rejection needed.
func TestSpikeIsDampedByTheBucketEMA(t *testing.T) {
m := NewModel(8000)
m.MaxPlausibleW = 17250
start := time.Date(2026, 7, 1, 4, 0, 0, 0, time.UTC)

// Settle the bucket at 400 W, past the exact-running-mean phase.
for i := 0; i < 40; i++ {
m.Update(start.Add(time.Duration(i)*time.Minute), 400, HeatingReferenceC)
}
before := m.Predict(start, HeatingReferenceC)
m.Update(start.Add(41*time.Minute), 11000, HeatingReferenceC)
after := m.Predict(start, HeatingReferenceC)

moved := after - before
if moved <= 0 {
t.Error("a real 11 kW reading should move the estimate up")
}
// alpha = 0.1, so one sample carries a tenth of the gap and no more.
if moved > 0.15*(11000-400) {
t.Errorf("one spike moved the hour by %.0f W — EMA is not damping it", moved)
}
}

// A fault must touch nothing on its way out — not the buckets, not MAE,
// and not the heating coefficient. The physical bound used to run after
// the online heating fit, so a cold-weather meter fault moved
// HeatingW_per_degC while Update still reported no update applied, and a
// run of faults could walk the coefficient to its ceiling. Codex P2 on
// PR #742.
//
// Every sample here stays inside one hour-of-week bucket: the heating fit
// is gated on that bucket's trust, so a fault landing in a fresh bucket
// would be filtered by the gate rather than by the bound, and the test
// would pass either way without proving anything.
func TestImplausibleLoadDoesNotMoveHeatingCoefficient(t *testing.T) {
m := NewModel(4000)
m.MaxPlausibleW = 11000
start := time.Date(2026, 1, 5, 12, 0, 0, 0, time.UTC)
const coldC = 0.0 // well past HeatingMinDeltaT

// Warm the bucket past MinTrustSamples so the fit is ungated, and hold
// the load below the learned mean so the residual — and therefore the
// coefficient — is driven somewhere a fault could visibly move it.
for i := 0; i < 20; i++ {
m.Update(start.Add(time.Duration(i)*time.Minute), 1200, coldC)
}
idx := HourOfWeek(start)
if m.Bucket[idx].Samples < MinTrustSamples {
t.Fatalf("warmup left the bucket untrusted (%d samples) — the fit would be gated, not bounded",
m.Bucket[idx].Samples)
}

before := m.HeatingW_per_degC
beforeMAE := m.MAE
beforeSamples := m.Samples

// Faults in the SAME bucket, so only the bound can stop them.
for i := 20; i < 60; i++ {
at := start.Add(time.Duration(i) * time.Minute)
if HourOfWeek(at) != idx {
t.Fatalf("sample %d escaped the bucket under test", i)
}
if m.Update(at, 50000, coldC) {
t.Fatal("an implausible reading was accepted")
}
}

if m.HeatingW_per_degC != before {
t.Errorf("heating coefficient moved on rejected faults: %.4f → %.4f",
before, m.HeatingW_per_degC)
}
if m.MAE != beforeMAE {
t.Errorf("MAE moved on rejected faults: %.1f → %.1f", beforeMAE, m.MAE)
}
if m.Samples != beforeSamples {
t.Errorf("sample count moved on rejected faults: %d → %d", beforeSamples, m.Samples)
}
}
11 changes: 7 additions & 4 deletions go/internal/loadmodel/service.go
Original file line number Diff line number Diff line change
Expand Up @@ -61,7 +61,7 @@ type Service struct {
}

// NewService constructs + restores from state if present.
func NewService(st *state.Store, tel *telemetry.Store, siteMeter string, peakW float64) *Service {
func NewService(st *state.Store, tel *telemetry.Store, siteMeter string, peakW, maxPlausibleW float64) *Service {
s := &Service{
Store: st,
Tele: tel,
Expand All @@ -75,6 +75,7 @@ func NewService(st *state.Store, tel *telemetry.Store, siteMeter string, peakW f
}
for _, profile := range Profiles() {
s.models[profile] = newProfileModel(peakW, profile)
s.models[profile].MaxPlausibleW = maxPlausibleW
}
if st != nil {
loadedProfiles := make(map[Profile]bool)
Expand All @@ -85,7 +86,7 @@ func NewService(st *state.Store, tel *telemetry.Store, siteMeter string, peakW f
}
for _, profile := range Profiles() {
if js, ok := st.LoadConfig(stateKey(profile)); ok && js != "" {
if m, ok := restoreModel(js, peakW, profile); ok {
if m, ok := restoreModel(js, peakW, maxPlausibleW, profile); ok {
s.models[profile] = m
loadedProfiles[profile] = true
slog.Info("loadmodel restored",
Expand All @@ -99,6 +100,7 @@ func NewService(st *state.Store, tel *telemetry.Store, siteMeter string, peakW f
if err := json.Unmarshal([]byte(js), &m); err == nil && m.Alpha > 0 {
if !loadedProfiles[ProfileHome] {
m.PeakW = peakW // config may have changed
m.MaxPlausibleW = maxPlausibleW
if m.PriorScale <= 0 {
m.PriorScale = 1
}
Expand All @@ -125,12 +127,13 @@ func (s *Service) SetSiteMeter(name string) {
s.mu.Unlock()
}

func restoreModel(js string, peakW float64, profile Profile) (*Model, bool) {
func restoreModel(js string, peakW, maxPlausibleW float64, profile Profile) (*Model, bool) {
var m Model
if err := json.Unmarshal([]byte(js), &m); err != nil || m.Alpha <= 0 {
return nil, false
}
m.PeakW = peakW // config may have changed
m.PeakW = peakW // config may have changed
m.MaxPlausibleW = maxPlausibleW // ditto — fuse size is editable
if m.PriorScale <= 0 {
m.PriorScale = newProfileModel(peakW, profile).PriorScale
}
Expand Down