@rssdev10 rssdev10 commented Nov 26, 2026 •

Copy link
Copy Markdown
Owner

Prepares the Bluetooth LE protocol library for crates.io as alientek-el15 and keeps the el15 app in the same repository. While doing it, several bugs were found and fixed; each fix was measured on a real EL15 (HW 2.0 / SW 1.7).

Restructure (same pattern as skyrc-mc5000)

  • el15-bt/ moves to alientek-el15/. The library has its own version, starting at 0.1.0, and tags alientek-el15-v<version>. The app keeps the workspace version and v* tags.
  • Added crates.io metadata, a crate README with a read-only example, a CHANGELOG, examples/status.rs, and LICENSE as a real file (not a symlink).
  • The apps depend on the library by path + version. el15-app, el15-scpi and scpi-test have publish = false. The README documents how another project can use a local checkout (path or [patch.crates-io]).
  • Bluetooth is the default ble feature. Without it the crate depends only on thiserror. serde is opt-in.
  • tokio is limited to rt, sync and time.
  • release.yml attaches the current library .crate to every app release.
  • tests.yml:
    • clippy runs on all targets
    • the library is linted and tested without default features
    • its docs are built with RUSTDOCFLAGS=-D warnings
    • cargo publish --dry-run runs on it
  • Provenance: the protocol was reverse-engineered from the traffic of ALIENTEK's Android app ATK-xTOOL and cross-checked against DM40GUI. It is not a port of DM40GUI.

Breaking API changes (0.1.0 vs el15-bt 0.1.4, all listed in the CHANGELOG)

  • Prefixes dropped:
    • EL15Status → Status
    • EL15_SERVICE_UUID → SERVICE_UUID
    • HEADER → STATUS_HEADER
  • parse_status_packet returns Result<Status, ParseError>. It rejects a wrong length, wrong header or bad checksum. Before this, a corrupted packet came back with crc_pass: false, valid: true and was emitted as a measurement.
  • Status keeps measurements only:
    • The display strings are removed: mode_name, setpoint unit/label/decimals, raw_hex.
    • warning is Option<Warning>.
  • The firmware version is a FirmwareVersion struct whose Display is unchanged.
  • build_set_setpoint_cmd and build_set_cap_current_cmd return Result and refuse NaN, infinity and negative values. f32::clamp keeps NaN, so typing nan as the CAP current used to put NaN on the wire.
  • Removed MODE_NAMES and Device::watch_central_events. Error is #[non_exhaustive].

Fixes measured on the device

Write pacing. An unpaced three-command burst (mode CAP, setpoint, CAP current) lost the mode switch 4 times out of 6. Device::send now waits 120 ms after the previous write from any task, which also paces init_handshake. With that, the same burst took effect 6/6 with 18/18 ACKs.

Gap Mode switch took effect ACKs
0 ms 2/6 9/18
30 ms 5/6 12/18
60 ms 6/6 13/18
120 ms (or library pacing) 6/6 18/18

Read-only queries were never lost. 300 polls came back as 300 single 28-byte notifications with valid checksums.

Characteristics. The device exposes FFF1/FFF2/FFF3 under FFF0 only. connect now prefers FFF1 and no longer falls back to characteristics of other services.

DCR unit is milliohms, not Ohms. On a Li-ion cell, the voltages at the two test currents (4.1693 V at 24.8 mA, 3.9998 V at 1001.3 mA) give 173.6 mΩ. The device reported 173.15. The docs said Ohms. The field keeps the name dcr_mohm, the CLI label is fixed, and a unit test uses the captured packet.

SCPI. MEAS:DCR? now returns Ohms (the SCPI base unit, like MEAS:RES?) instead of passing the device's mΩ value through.

GUI. The DCR panel showed 0.00 °C, but DCR packets carry no temperature. It now shows ---.

Opcode 0x06 = set device name (docs only, no builder). An earlier probe had overwritten the name with 14 00 …. Writing "EL15" restored the INFO reply byte-for-byte to the official app's capture. The advertised BLE name (_BLE) did not follow on reconnect.

Checks (local, rustc / clippy 1.100.0)

  • cargo test --workspace: library 26 tests, app 49 tests, all passing
  • cargo clippy --workspace --all-targets -- -D warnings: clean
  • cargo clippy -p alientek-el15 --all-targets --no-default-features -- -D warnings: clean
  • cargo test -p alientek-el15 --no-default-features: 22 tests passing
  • cargo clippy -p alientek-el15 --all-targets --all-features -- -D warnings: clean
  • RUSTDOCFLAGS=-D warnings cargo doc -p alientek-el15 --no-deps: clean
  • cargo publish -p alientek-el15 --dry-run: OK

Not in this PR: the AI-assistant instruction files (CLAUDE.md, AGENTS.md, .github/copilot-instructions.md) were updated locally but will be committed separately.

Designed by Claude.

🤖 Generated with Claude Code

rssdev10 and others added 11 commits November 26, 2026 23:28
- el15-bt/ moves to alientek-el15/; the library starts its own version line
  at 0.1.0, the apps keep the workspace version
- crates.io metadata, crate README, CHANGELOG, LICENSE (a real copy) and a
  read-only example
- apps depend on it by path and version and are not published
- provenance: reverse-engineered from the official Android app ATK-xTOOL,
  cross-checked against DM40GUI (not a port of it)
- release.yml attaches the library .crate to every app release
- CI lints all targets, checks the library docs and a publish dry run
- tokio: rt (the notification pump task), sync (its channel) and time
  (scan timeouts, command pacing); the example uses the full runtime
The crate name already says EL15. Breaking:
- EL15Status becomes Status, EL15_SERVICE_UUID becomes SERVICE_UUID,
  HEADER becomes STATUS_HEADER, Status::dcr_mohm becomes dcr_ohm (Ohms)
- parse_status_packet returns Result<Status, ParseError> and rejects a
  wrong length, header or checksum; a corrupted packet used to be emitted
  as a measurement (crc_pass false but valid true)
- firmware version is a FirmwareVersion struct (same Display text); it and
  the CAP current reply check their checksum
- Status keeps measurements only: the display strings (mode_name, setpoint
  unit/label/decimals, raw_hex) go; warning is Option<Warning>
- MODE_NAMES and Device::watch_central_events are removed; Error is
  non_exhaustive and keeps only the variants it returns
- without `ble` the crate keeps the frames, the checksum and the parsers,
  and depends only on thiserror
- INTER_COMMAND_GAP moves to protocol: it is a fact about the device, not
  about btleplug
- serde becomes opt-in; the apps do not serialize library types
- CI lints and tests the library without default features

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Tested on the device (HW:2.0 / SW:1.7, load off):
- an unpaced 3-command burst (mode CAP, setpoint, CAP current) lost the
  mode switch 4/6 at 0 ms and 1/6 at 30 ms; ACKs went missing up to 60 ms
- Device::send now waits out INTER_COMMAND_GAP since the previous write
  from any task and never overlaps writes, so send, send_sequence and
  init_handshake are all paced; the same burst then took effect 6/6
- the device exposes FFF1/FFF2/FFF3 under FFF0 only; connect prefers FFF1
  and no longer falls back to a characteristic of another service

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
A DCR test on a Li-ion cell (I1 25 mA, I2 1000 mA) reported 173.15 in
bytes 23..27; the voltage drop between the two currents gives 173.6 mOhm.
The docs and the previous commits claimed Ohms; that was wrong.
- keep the field name Status::dcr_mohm, now documented as milliohms
- the GUI card was right; the CLI debug output labelled it Ohm
- unit test from the captured packet

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
…mbers

Breaking: build_set_setpoint_cmd and build_set_cap_current_cmd return
Result<Vec<u8>, InvalidValue>.
- NaN, infinity and negative values are refused; f32::clamp keeps NaN, so
  typing "nan" as the CAP current used to put NaN on the wire
- the CAP current above 12 A is refused instead of silently clamped; a
  setpoint above 7500 (CR's limit, SETPOINT_MAX) is refused
- the GUI and CLI log or print the refusal and send nothing; SCPI skips
  both the frame and the stored setpoint
DCR status packets carry the I1/I2 test currents where other modes carry
the temperature, so the card always read 0.00 °C. It now shows "---".
Found while checking why the info reply read `14 00 ...` instead of
"EL15": an earlier 10-byte 0x06 probe had been stored as the name.
Writing "EL15" with 0x06 restored the reply byte-for-byte to the official
app's capture. No builder is added.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
The device reports the DCR result in milliohms and MEAS:DCR? passed that
number through. SCPI replies use base units, as MEAS:RES? already does,
so convert to Ohms. Documented in SCPI_PROTOCOL.md.