Skip to content

File downloads: paced by the channel, with a real fallback to smaller blocks - #56

Merged
robdobsn merged 1 commit into
mainfrom
feature/transfer-flow-control
Nov 15, 2026
Merged

robdobsn merged 1 commit into
mainfrom
feature/transfer-flow-control

Conversation

@robdobsn

Copy link
Copy Markdown
Owner

Why

  • Downloads were paced by a fixed 100 ms between blocks on every link (50 kB/s over WiFi, 5 kB/s over BLE).
  • Over the USB serial console, downloads with 5,000-byte blocks failed: the console offered blocks its transport could not send, they were dropped silently, and nothing fell back to a smaller size.

What changed

  • Pacing: the next block is sent when the last has left the channel's outbound queue (CommsCoreIF::outboundQueuedCount(), new) and the transport is ready (outboundCanAccept()), within the ack window.
  • Start: the first block waits for the client's first dfAck, or 200 ms. Without the 100 ms gap, a block sent straight after the reply to dfStart could reach a client before it had handled that reply, and clients ignore blocks for a download they have not set up (seen as a 3 s pause at the start of some WiFi downloads). Released raftjs already acks at once.
  • Fallback: when nothing is acknowledged for 3 s, the block size is halved (down to 64 bytes) before resending.
  • CommsChannelMsg::setAckedByProtocol(): blocks are marked as covered by the protocol's own acks, so a transport need not confirm each packet (BLE uses notifications for them).

Results (ESP32-S3 Axiom, with the matching RaftSysMods and RaftWebServer PRs)

Link Before After
USB serial failed 320-330 kB/s
WiFi 48 kB/s 125 kB/s (190-200 with the TCP settings in the wiki)
BLE 5 kB/s 50-52 kB/s

A TinyS3 built without PSRAM gives 230 kB/s over serial and 44 kB/s over BLE.

Testing

  • linux_unit_tests: new test_file_download_okto; make check passes.
  • Hardware: Axiom018 and a TinyS3 over serial, WiFi and BLE with raftpy; released and new raftjs over WiFi.

Notes

  • Depends on nothing else to build. The speed-up on serial and BLE needs the RaftSysMods PR, and WiFi needs the RaftWebServer PR (without it a burst can overflow the WebSocket send queue).
  • Details: devdocs/file-transfer-flow-control.md in raftpy.

🤖 Generated with Claude Code

…l fallback to smaller blocks

- Blocks are sent when the last has left the channel's outbound queue (CommsCoreIF::outboundQueuedCount) and
  its transport is ready (outboundCanAccept), within the ack window, instead of one every 100 ms
- The first block waits for the client's first dfAck (clients ack as soon as they are ready to receive), or
  200 ms: a block sent straight after the reply to dfStart can reach a client before it has handled the reply
- When nothing is acknowledged for 3 s the block size is halved (down to 64 bytes) before resending, in case
  the channel offers blocks its transport can't deliver
- Blocks are marked as acknowledged by the protocol (CommsChannelMsg::setAckedByProtocol), so a transport
  needn't confirm each packet (BLE sends them as notifications)
- test_file_download_okto

Measured on an ESP32-S3 (Axiom): USB serial 320 kB/s (downloads of 5000-byte blocks failed before), WiFi
125 kB/s (48), BLE 50 kB/s (5), with the matching RaftSysMods and RaftWebServer changes.

Co-Authored-By: Claude Fable 5.2 <noreply@anthropic.com>
@robdobsn
robdobsn merged commit 0f21b0f into main Nov 15, 2026
1 check passed