Scalar S21 measurement (magnitude only) with ADALM-PLUTO Rev.B (AD9363) over 70–6000 MHz. The board runs a range-extended firmware (reported as a 1×1 device); only one RX/TX path is wired, so no phase, S11 or S12/S22.
Status: complete — CLI and GUI, thru calibration, report PNG/PDF and optional Touchstone export. Hardware: calibrated thru −0.02 dB mean (std 0.30 dB) over 70–6000 MHz. Manuals: measurement guide, calibration guide. Both are also available from the GUI Help menu (F1 opens the measurement guide). Design and measurement notes: docs/design.md.
- PlutoSDR Rev.B on AD9363, firmware v0.38-dirty with the range extension.
- One RX / one TX: measurement path is
TX1 → DUT → RX1. - Host: Ubuntu 26.04, Python 3.14, libiio 0.26.
- URI:
ip:192.168.2.1(shared) orusb:3.3.5(exclusive).
Requirements:
- Python 3.10 or newer;
- the libiio shared library (
libiio0/libiio-devon Debian/Ubuntu) — thepylibiiopackage is only a binding and needs it at import time; - an ADALM-PLUTO reachable over USB or network.
git clone https://github.com/ra4hgn/pluto-analyzer.git
cd pluto-analyzer
python3 -m venv .venv
source .venv/bin/activate
python -m pip install --upgrade pip
pip install -e .The package installs two entry points: pluto-na (GUI) and pluto-na-cli
(command line). All examples below assume the virtual environment is active.
If numpy/scipy/PyQt6 are already installed system-wide (PEP 668 hosts), create
the environment with --system-site-packages; requirements.txt pins the
Python bindings that match libiio 0.26:
python3 -m venv --system-site-packages .venv
source .venv/bin/activate
pip install -r requirements.txt
pip install -e . --no-deps# capabilities and span validation
pluto-na-cli info
pluto-na-cli info --uri usb:3.3.5
# one sweep, 70..6000 MHz, 500 points -> results/<timestamp>/trace.csv + meta.json
pluto-na-cli measure
pluto-na-cli measure --start 70 --stop 6000 --points 500 \
--dwell-ms 100 --out results/run1
pluto-na-cli measure --points 1 --start 900 --stop 900 # single pointUseful options: --if-khz, --fs-mhz, --samples, --captures,
--tx-gain, --rx-gain, --json, --quiet, --uri.
The board is shared. Before a sweep the tool watches DDS/LO/rate/gain for
~1 s (PlutoVNA.check_quiet). If another client changes them, measure stops
with exit code 4 and prints what changed:
ERROR: the Pluto is being reconfigured by another client (changed: dds_enabled).
Free the device or use --allow-busy to measure anyway.
--allow-busy overrides the check (the trace is then marked as suspect).
Free the device (stop other streams/tools) before a real measurement.
Output:
trace.csv—freq_hz, lo_hz, tone_hz, captures, amplitude, dbfs, peak, clip, low(no calibration applied yet, so values are dBFS).meta.json— app version, URI, fullSweepConfig, hardware capabilities, warnings and summary (min/max/mean, CLIP/LOW counts, duration).CLIPis derived from the ADC peak and may fire on a transient even when the lock-in tone is weak;LOWmeans |signal| < −90 dBFS.
# reference sweep with the fixture (cables + 10 dB attenuator) in place
pluto-na-cli cal --points 21 --start 70 --stop 6000 --out cal/s21_thru
# calibrated measurement: trace.csv gets an s21_db column
pluto-na-cli measure --cal cal/s21_thru --points 21 \
--start 70 --stop 6000 --out results/run1Accepted result: calibrated thru reads 0.00 ± 0.65 dB over 70 MHz–6 GHz (std 0.30 dB), a 10 dB gain-step check gives −10 ± 0.4 dB.
Offset (dB) / --offset-db adds a constant to the calibrated S21. Use it when
the reference path contains a known pad: calibrate with a 10 dB pad, then set
Offset = -10 to display a 30 dB DUT as −30 dB (measured difference −20 dB).
Keep Tone/RX/TX gains identical between calibration and measurement.
pluto-na-cli measure --cal cal/s21_thru --points 101 \
--start 70 --stop 6000 --out results/run1 \
--png results/run1/report.png \
--pdf results/run1/report.pdf \
--touchstone results/run1/trace.s2p- report PNG/PDF: matplotlib, title, min/max annotations, footer with points, calibration flag, URI and UTC date;
- Touchstone
.s2p: measured |S21| in[DB], phase written as 0°, S11/S12/S22 are −100 dB placeholders, header warnings. Magnitude only — not for phase-sensitive analysis.
In the GUI the same is available via Report PNG and Touchstone buttons.
pluto-naEnglish interface, PyQt6 + pyqtgraph:
- URI selector:
ip:192.168.2.1,usb:, custom; Connect/Disconnect; - sweep fields: start/stop MHz, points, IF, dwell, RX/TX gain, captures;
- Run / Stop / Continuous, progress and per-point status with CLIP/LOW/UNSTABLE;
- live curve plus raw points, Raw/Smoothed/Calibrated toggles; the smoothing window (moving average over frequency points, default 7) is in the View and Export row and is disabled when Smoothed is off — it only affects the displayed curve, exports use raw data;
- markers: left click adds a marker (MHz / dB), right click clears all;
- cursor readout, min/max/Δ in the status bar;
- Cal Thru / Load Cal / Clear Cal (calibration is applied automatically);
- Export CSV (+ JSON meta) and Export PNG;
- Help menu with the measurement and calibration guides (F1 opens the measurement guide) and an About dialog.
The SDR is owned by a worker thread (gui/worker.py); the GUI never touches
IIO directly. Closing the window stops the sweep and restores the Pluto.
Environment and dependency check:
python scripts/check_env.py
python scripts/check_env.py --uri ip:192.168.2.1Hardware capabilities and span validation:
python -m pluto_analyzer.hwcheck --uri ip:192.168.2.1Loopback test (connect TX → attenuator → RX), raw dBFS, no calibration:
python scripts/loopback_test.py \
--uri ip:192.168.2.1 \
--freqs 70,100,433,900,1300,2400,3500,5800,6000 \
--csv results/loopback.csvOptions: --if-khz 500, --fs-mhz 8, --samples 262144, --captures N,
--tx-gain -10, --rx-gain 50, --dwell-ms 100, --json.
- CW tone at IF = 500 kHz, complex TX buffer, cyclic.
- LO = f − IF (auto reverse-IF at the 70 MHz lower edge), detection at the signed IF; the probed RF frequency stays exactly on the grid.
- Lock-in: mix, block decimation by
fs/|IF|(sinc nulls at IF multiples), Hann-windowed coherent averaging. - Flags per point:
CLIP(ADC peak ≥ 0.8 FS) andLOW(|S21| below −90 dBFS). - Only |S21| is measured; Touchstone export will be optional and marked.
- Working defaults:
tx_gain=0(the Pluto TX attenuator has one usable step; intermediate values make the TX path unstable),rx_gain=10for aTX → 10 dB attenuator → RXloopback, dwell 300 ms, 3/2 captures below/above 1 GHz with median combining,tone_settle=300 msafter buffer reload. - The Pluto's AD9361 gain table ends at 4 GHz (
gaintable ... end=4000000000), so the reference level has a step of several dB around 4.04 GHz. Calibrate with the same or denser grid than the measurement; a 21-point calibration cannot resolve this step and produces spikes near 4 GHz. AD9363 is only specified up to 3.8 GHz anyway.
- Use
adi.Pluto(oradi.ad9364), notadi.ad9361: the latter expects two RX channels and fails withChannel voltage2 not foundon this 1×1 board. - Writing
sample_ratethrough pyadi enables the AD9361 FIR filter (filter_fir_en=1, rate range 0.52–30.72 MSPS). The loopback script reads the device state before configuring it and restores it afterwards (sample rate, gains, bandwidths, LOs and the FIR enable flag), so the shared Pluto is left as it was found. - Fixed defaults that reproduce the factory idle state: 30.72 MSPS, FIR off,
slow_attack, LO 5.76 GHz, RF BW 18 MHz.
Qt 6 auto-selects the GTK3 platform theme on GNOME; the plugin reads
org.gnome.settings-daemon.plugins.xsettings antialiasing, which recent GNOME
releases removed, and GLib aborts the process. pluto-na now detects this
(probes gsettings) and drops the GNOME desktop hints before creating
QApplication, so Qt uses its built-in theme.
PLUTO_NA_KEEP_THEME=1 pluto-nakeeps the system theme if your schema is fixed.- For a native-looking theme install
qt6ctand run withQT_QPA_PLATFORMTHEME=qt6ct PLUTO_NA_KEEP_THEME=1 pluto-na. - Alternatively remove the broken plugin package (
qt6-gtk-platformtheme).
src/pluto_analyzer/ package: SDR wrapper, DSP, sweep engine, calibration,
export, CLI and the PyQt6 GUI
scripts/ standalone hardware/environment checks and helpers
tests/ hardware-independent unit tests (unittest)
docs/design.md methodology, hardware constraints and limitations
docs/*.png example report and calibration plots
src/pluto_analyzer/help/ measurement and calibration guides (shown in Help)
Generated data is not part of the repository: cal/ holds calibration files
created by pluto-na-cli cal, results/ holds sweeps and reports.
The unit tests do not need a PlutoSDR attached: