Include tmax in the phonon temperature grid and default to 1000 K, matching phonopy - #1568
Merged
Merged
Conversation
The thermodynamic properties in the atomate2 phonon document were computed on np.arange(tmin, tmax, tstep) with a default tmax of 500, so the default grid stopped at 490 K. The default is now 1000 K and tmax is included in the grid, matching phonopy's run_thermal_properties. Closes materialsproject#1567 Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Member
|
@computron I am fine with it. I don't have a large scale study with this workflow. Thus, I believe it is really up to you and @hrushikesh-s to decide. 😃 |
Collaborator
|
Also good with me - can I mark as ready for review instead of a draft? |
Collaborator
|
Looks good to me as well! |
computron
marked this pull request as ready for review
October 2, 2026 18:44
Member
Author
|
ok great marked as ready |
JaGeo
enabled auto-merge (squash)
October 2, 2026 19:17
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Sign up for free
to join this conversation on GitHub.
Already have an account?
Sign in to comment
Add this suggestion to a batch that can be applied as a single commit.This suggestion is invalid because no changes were made to the code.Suggestions cannot be applied while the pull request is closed.Suggestions cannot be applied while viewing a subset of changes.Only one suggestion per line can be applied in a batch.Add this suggestion to a batch that can be applied as a single commit.Applying suggestions on deleted lines is not supported.You must change the existing code in this line in order to create a valid suggestion.Outdated suggestions cannot be applied.This suggestion has been applied or marked resolved.Suggestions cannot be applied from pending reviews.Suggestions cannot be applied on multi-line comments.Suggestions cannot be applied while the pull request is queued to merge.Suggestion cannot be applied right now. Please check back later.
Summary
Closes #1567. This implements option (ii) from the issue: the phonon temperature grid now includes
tmax, and the defaulttmaxis 1000 K, matching phonopy'sPhonopy.run_thermal_properties.Previously the thermodynamic properties in the atomate2 phonon document (
temperatures,free_energies,entropies,internal_energies,heat_capacities) were computed onnp.arange(tmin, tmax, tstep)withtmax=500, so the default grid stopped at 490 K. The grid is nownp.arange(tmin, tmax + tstep / 2, tstep), so the default is 0, 10, ..., 1000 K (101 temperatures).src/atomate2/common/schemas/phonons.py: defaulttmaxof 1000 K, and the endpoint is included.tests/vasp/flows/test_phonons.py: new test that checks the default grid (0-1000 K) and that an explicittmaxis included. It fails on the old code and passes on the new one.tests/torchsim/flows/test_phonons.py: pinstmax=400so the existing 0-400 K reference values stay as they are.Behavior change: anyone who already passes
tmaxnow also gets a value attmaxitself, as in phonopy.Not changed: the thermal displacement grid (
tmax_thermal_displacements, default 500 K) andt_maxofcalc_thermo_dataincommon/jobs/qha.py(default 500 K). Only the defaultatomate2phonon document schema is affected; theemmetschema computes thermodynamic quantities at the temperatures you ask for.Additional dependencies introduced (if any)
None.
Checklist