esf — empirical stress factor degradation model

tests docs

esf models Li-ion battery degradation as a product of empirical stress factors (temperature, SoC, DoD, time) scaling a nonlinear SEI-driven capacity loss. It does two things:

  1. Fitting — extract the model parameters from calendar-aging and cycle-life data.
  2. Simulation — predict capacity loss for a drive cycle (rainflow cycle counting → stress factors → loss), given a set of parameters.

Early release. This is a first public version. Expect bugs, incomplete features, and possible API changes. Please open an issue if something looks wrong.

Based on Xu et al., "Modeling of Lithium-Ion Battery Degradation for Cell Life Assessment", IEEE Trans. Smart Grid 9(2), 2018 (https://ieeexplore.ieee.org/document/7488267), adapted at IFE. Provenance, the rainflow/stress-factor background, and the original data sets are described in docs/background-notes.md. The fitting workflow (user walkthrough + the architecture of the fitting code) is documented in docs/fitting-architecture.md, with a runnable end-to-end example in scripts/examples/full_fitting_workflow.py.

Installation

With uv (recommended — this is what CI uses):

git clone https://github.com/ife-bat/esf.git
cd esf
uv sync --dev
uv run pytest        # everything should pass

Or with pip: pip install -e . (add --group dev for the test dependencies) in your environment of choice.

Quick start

Simulate degradation for a drive cycle

import numpy as np
import esf

prms = esf.get_example_params()          # parameters from the Xu et al. paper
drive_cycle = esf.drive_cycle_001(verbose=False)   # example: time/soc/c-rate/temperature frame

result = esf.drive_cycle_degradation_calculator(
    drive_cycle, prms, cycle_numbers=np.linspace(1, 1000, 20)
)
print(result[["cycle_number", "loss", "soh"]].tail())

cycles_to_eol = esf.calc_cycle_at_end_of_life(
    result["f_c"].iloc[0], result["f_t"].iloc[0], prms, eol_soh=0.8
)

Any drive cycle works as long as the frame has time (s), soc (0–1), c-rate, and temperature (K) columns; esf.load_drive_cycle reads CSV power profiles.

Fit parameters from aging data

The two-stage procedure: fit the nonlinear SEI model at reference conditions, extract per-condition degradation rates, then fit each stress factor.

import esf

data = esf.SampleData()
data.add_data(                       # frame with t / SoH / T columns
    frame,
    data_type=esf.DataType.CALENDAR_VS_TEMPERATURE,
    time_unit="days",
    temperature_unit="K",
)
data.calculate_life_fraction()

prms = esf.get_example_params()

# 1) SEI parameters at reference conditions (298.15 K)
esf.sei_fit_at_reference_conditions(
    prms, data.calendar_life_vs_temperature(filter_value=298.15, strict_mode=False)
)

# 2) one degradation rate per temperature
rates = esf.degradation_rates_fit(
    prms,
    data.calendar_life_vs_temperature(strict_mode=False),
    data_type=esf.DataType.CALENDAR_VS_TEMPERATURE,
)

# 3) the temperature stress factor from those rates
esf.temperature_stress_factor_fit(prms, rates)

prms.save_json("my_parameters.json")   # -> esf.ESFParams.load_json(...)

Every fit accepts verbose=True (report + plots) and a parameter_overrides dict for adjusting the lmfit parameters, e.g. parameter_overrides={"x_ref": {"value": 1.0, "vary": False}} or {"k__max": 0.9}. Unknown parameter names raise with the list of valid ones.

Units convention

Internal units, everywhere, after data ingestion:

Quantity Unit
time seconds
temperature K
SoC / DoD / SoH / loss fraction (0–1)
rate C-rate

Conversion happens only in esf.io (on the way in — add_data takes time_unit= / temperature_unit= and the selectors re-unit to the internal convention) and in plotting/reporting (on the way out). Reference values such as the calendar-time reference (x_ref = 86 400 s = 1 day) are model parameters, not hidden unit changes. All pint quantities must come from the single shared registry (from esf.settings.units import ureg, Q_).

Note in particular that the exponential temperature stress model is not invariant under a unit change (its x_ref/x factor differs between degC and K parameterizations) — temperatures are kelvin, always.

Repository layout

  • esf/ — the package
    • models/ — model equations (base_models), fitting (fitting), plot rendering (fit_plotting), the model register, rainflow counting
    • external/ — the vendored peak detector and the adapter onto the rainflow package (see THIRD-PARTY-NOTICES.md)
    • io/ — data containers (SampleData) and selectors
    • simulations/ — drive-cycle and DST degradation simulation
    • settings/ — ESFParams, enums, constants, the shared unit registry
    • utils/ — converters
    • data/ — aging data and example parameter files, shipped with the package
  • development/ — the working documents: repo review, design decisions, session plan (start here if you want to change the code)
  • docs/ — the documentation site (built with Zensical): background notes, the fitting architecture, and the workflow / reference pages
  • scripts/ — the runnable example (scripts/examples/full_fitting_workflow.py, executed by the tests)
  • tests/ — pytest suite (uv run pytest); runs in CI on linux and windows

Status

All fitting stages are implemented and verified numerically (synthetic-data recovery tests): the SEI fit (calendar and cycling), the SoC / temperature / time / DoD stress-factor fits, the multi-condition degradation-rates fit and the chained pipeline, rainflow counting, and the drive-cycle degradation simulation (pinned end-to-end regression). Beyond the core:

  • DoD stress-factor fit — both the reference-conditions path and the non-reference stress-removal path (Xu et al. eqs. 20/31); the model form is chemistry-selected (empirical/exponential/quadratic for LMO/LFP/NMC).
  • Uncertainty propagation — opt-in Monte-Carlo bands over the fitted covariance (ParameterUncertainty / ParameterEnsemble / simulate_with_uncertainty); the simulators stay float-only.
  • Publication reproduction — the seven DST degradation curves of the paper are reproduced within a stated tolerance (end-to-end regression test).
  • Prediction from field data — OperationalData turns a measured operating trace into a prediction.

Still open: the interactive apps, uncertainty Tier 2 (bootstrap) + per-point measurement noise, and LFP-specific validation. See the round plans under development/.

Full documentation (install, workflows, units, API, architecture) is built with Zensical from docs/ (uv run --group docs zensical serve).

The roadmap and the reasoning behind the current design live in development/session-plan.md and development/design-decisions.md.

Citing and licensing

esf is MIT licensed (LICENSE). Third-party components and their licenses are listed in THIRD-PARTY-NOTICES.md.

If you use this model in published work, cite the paper it implements:

B. Xu, A. Oudalov, A. Ulbig, G. Andersson and D. S. Kirschen, "Modeling of Lithium-Ion Battery Degradation for Cell Life Assessment," IEEE Transactions on Smart Grid, vol. 9, no. 2, pp. 1131–1140, March 2018. doi: 10.1109/TSG.2016.2578950

Contributors

Jonathan Fagerström Jinsong Hua Julia Wind Jan Petter Mæhlen

Jonathan Fagerström · Jinsong Hua · Julia Wind · Jan Petter Mæhlen

Acknowledgments

This work was supported by Jernbanedirektoratet (the Norwegian Railway Directorate) through the Europe's Rail project FP4-Rail4EARTH. The work within the Europe's Rail project FP4-Rail4EARTH is supported by the Europe's Rail Joint Undertaking and its members. The project is funded by the European Union. Views and opinion expressed are however those of the author(s) only and do not necessarily reflect those of the European Union or the Europe's Rail Joint Undertaking. Neither the European Union nor the granting authority can be held responsible for them.