  • The gateway now records how it answered each charger's last BootNotification (last_boot_status, last_boot_reason, last_boot_decided_at; Record how the last BootNotification was answered per charge point OCPP#268). The Console shows it, so "the backend has no device for this charge_point_id" no longer looks like a dead charger or like the gateway's own pending-authorization queue.
  • Badge in the charger detail header and on fleet rows and cards, a notice under the detail header, and a hint under "No connectors reported." when the boot was not Accepted. Remote start is disabled with that reason.
  • GET /sys/charge-points proxy with a whitelisted filter set, and a read-only "Waiting for backend registration" section on the Authorizations page. The section also filters on the client, so a gateway without the new field lists nothing there instead of every charger.

Test plan

  • vitest run (apps/web): 570 passed, including a case where the gateway returns rows without last_boot_status
  • pnpm -r typecheck: clean
  • pnpm -r lint (CI)
  • Detail page of a charger whose last boot was Pending shows the badge and the hint

Risk / blast radius

Read-only UI plus one proxied GET. Needs eveys-mobility/OCPP#268 deployed for the badges; without it the Authorizations section stays empty.

The gateway now records how it answered each charger's last
BootNotification (`last_boot_status`, `last_boot_reason`,
`last_boot_decided_at`). Surface it so an operator can tell "the
TOGER backend has no device for this charge_point_id" apart from the
gateway's own pending-authorization queue, instead of reading an
empty connector list as a dead charger.

- protocol: the three fields on `chargePointSummary`.
- web: `boot-decision.ts` maps status + reason to operator text;
  badge in the charger detail header and on fleet rows / cards, a
  notice under the detail header, and a hint under "No connectors
  reported." when the boot was not Accepted. `canRemoteStart` treats
  a non-Accepted boot as not startable with that reason.
- server: `GET /sys/charge-points` proxy with a whitelisted filter set
  (fail-soft like `/sys/authorizations`); `last_boot_status` accepted
  by the gateway client and the WS broker.
- Authorizations page: read-only "Waiting for backend registration"
  section that polls chargers whose last boot answer is Pending and
  links to the detail page.
- api-types: ChargePoint schemas in the OpenAPI copy carry the new
  fields.