Repository files navigation

OpenOSC

Total release downloads ZT703S firmware downloads ZT706S firmware downloads Latest release GitHub stars

Open-source firmware for the ZT703S and ZT706S handheld oscilloscope multimeters.

OpenOSC replaces the stock application with its own oscilloscope, multimeter and signal generator firmware. It also adds a small Recovery bootloader that updates the firmware from a USB drive.

Documentation: the wiki has a user guide for every instrument, the SCPI reference, troubleshooting and pages for contributors.

Status: work in progress. ZT703S is the main development and test device. ZT706S: I don't have one. Users run it, but many features are untested on that model. Clones of the ZT703S and ZT706S should work too: install the files for the model they are based on. If something does not work on a clone, please open an issue.

Warning

This firmware is for enthusiasts only. If you are generally happy with the stock firmware, I do not recommend installing OpenOSC.

I take no responsibility for bricked or damaged devices. You install this firmware entirely at your own risk.

Note

You can always go back to the stock firmware. OpenOSC never modifies the factory bootloader, your calibration or the factory settings. The factory bootloader still accepts official updates, so installing the official firmware replaces OpenOSC completely. See Going back to the stock firmware.

Screenshots

Captured on a ZT703S running OpenOSC.

Oscilloscope: 20 kHz and 40 kHz square waves with frequency, duty and period readouts, soft-keys at the bottom Multimeter: AC voltage RMS with MIN/MAX/AVG statistics and bar graph
Oscilloscope, two channels Multimeter with statistics
Oscilloscope: two readouts per channel, time cursors and the STOP status word Multimeter: large 80 px reading under the analog dial
Two readouts per channel, time cursors Multimeter, large reading
Performance settings: Interleave CH1 on, 200 MS/s Scope calibration: interleave offset of +9.8 codes saved for 200 MHz
CH1 interleave on the ZT703S (experimental) Interleave offset calibration
Bode analyzer: gain and phase of an RC filter from 100 Hz to 200 kHz Multimeter: Type K thermocouple reading 22.5 °C
Bode analyzer Type K temperature
Protocol decoder, split view: SPI waveform above, decoded table below Protocol decoder: CAN frames table with IDs, data and status
Protocol decoder: split view (SPI) Protocol decoder: CAN table
Protocol decoder: I2C transactions table with addresses and data Protocol decoder: detail of a CAN FD frame with its 64-byte payload
Protocol decoder: I²C table CAN FD frame detail
Protocol decoder: UART frames table Decoder settings: UART baud rate detected automatically
Protocol decoder: UART table UART baud rate detection
Multimeter analog view: dial with REL reference and statistics Signal generator: sine at 1 kHz with frequency, waveform preview and soft-keys at the bottom
Multimeter, analog view Signal generator
Multimeter HOLD settings: Manual, Delayed, Stable and Auto modes Multimeter in Auto HOLD: a stable reading held automatically
Multimeter HOLD modes Auto HOLD
Oscilloscope with the Daylight color scheme Oscilloscope with the Amber color scheme
Daylight color scheme Amber color scheme
Channel menu with the F1-F4 cards at the bottom, above the physical keys Generator layout editor: choosing the position of the frequency, preview and buttons blocks
Menus above the F1–F4 keys Generator layout
FFT, Blackman window, 2048 points, with frequency cursors XY mode: two square waves in quadrature
FFT with cursors XY mode

Features

Oscilloscope

  • Two channels, 20 mV/div to 10 V/div, timebase from 10 ns/div to 20 s/div
  • Trigger modes Auto, Normal and Single, with adjustable pre/post-trigger position and Center trigger. Tap F3 to select Trigger and use Left/Right to adjust pretrigger. Tap F3 again to cycle modes. Hold F3 to set the trigger level to the signal midpoint and pretrigger to 50%. Pan with F2
  • Continuous Roll mode for slow timebases (200 ms/div and slower)
  • In the default Quick profile, tap AUTO to start Auto Setup or cancel it in progress. Hold AUTO for 2 s in Y-T to open Zoom & Pan. Up/Down zoom the view, Left/Right pan, and F4 returns to the previous card. The Classic profile uses a tap to reset pan and a hold to start Auto Setup. Choose the profile and the F2/F4 hold actions in Settings → Display → Scope shortcuts
  • Hold F1 to choose the selected channel's probe ratio, including 10000:1 (X10K on the Position card). Hold F2 for Home view or Reset zoom & pan. Hold F4 to open the assigned editor. Returning from the Cursor settings shortcut selects the first enabled cursor for arrow-key control
  • Configurable on-screen measurements, two per channel in the footer, time and level cursors
  • Hardware frequency counter with an averaged on-screen overlay
  • XY, MATH and reference waveforms; sin(x)/x and spline interpolation, fading or infinite persistence, Glow
  • Per-channel waveform density (Channel → Density) in Y-T and Y-T+FFT. Choose Colors to show rare paths in cooler colors and frequent paths in warmer colors, or Mono with a selectable color. Density defaults to Off. Its history follows Analyze → Display → History → Persistence. Density uses a 1 s history with Persistence Off. Infinite keeps every observed path, and Clear history and reference starts a new accumulation
  • Grid brightness (Analyze → Display → View → Grid brightness, 0–100 %) and a separate trace brightness for CH1 and CH2 (Channel → Trace brightness, 10–100 %). Both dim towards the plot background on dark and light schemes. Trace brightness also applies to Peak Hold, Persistence, Glow, X-Y (CH1) and Density. Channel colors, labels and markers keep full contrast
  • FFT up to 2048 points with four window functions, dBFS or linear scale
  • Protocol decoders (Analyze → Decoder): UART with autobaud, I²C, SPI, LIN, CAN and ISO CAN FD. Waveform with annotations, split or table view, event detail; decoded data saved as CSV
  • Bode analyzer (Analyze → Bode (FRA)): gain and phase of a circuit against frequency with the built-in generator, cursors, −3 dB points, bandwidth, gain and phase margins, CSV export
  • Zero and gain calibration of both channels, stored as files and never written to the factory calibration
  • Selectable performance profiles: 200/100, 280/140 and 360/90 (core MHz / MS/s per channel), switched instantly without a restart
  • CH1 interleave over both ADCs, up to 280 MS/s on CH1 alone. Both models offer Off, On and Auto. On the ZT703S, interleave is experimental, with on-device offset and gain/timing calibration. Its Auto mode follows the MKR rule: CH1 alone at 10 or 25 ns/div on the 200 and 280 MHz profiles, except in Roll or while the generator streams from the DAC. On interleaves CH1 alone at every timebase and profile. The ZT703S defaults to Off and the ZT706S to Auto (the stock rule)
  • Save waveforms as RAW or CSV

Multimeter

  • DC/AC voltage, millivolts, DC/AC current and milliamps, resistance, continuity, diode, capacitance
  • Type K thermocouple temperature in °C or °F. In Measurement → Junction source, choose Manual (25 °C by default), MCU at startup, or MCU live. The startup option holds the die temperature captured when the firmware launches. The live option updates it about once a second. As the instrument warms up, die temperature can diverge from the temperature at the thermocouple terminals.
  • Auto and manual ranges (the AUTO/RANGE key works as in the stock firmware) and REL
  • HOLD modes (MENU → Measurement → Hold): Manual, Delayed (after a countdown), Stable (waits for a stable reading) and Auto (holds every new stable reading)
  • Statistics, trend chart and CSV logging
  • Large 72/80 px reading when the bar graph and statistics are off
  • Bar graph and analog dial scaled to the meter's range: 25,000 counts on ZT703S, 66,000 on ZT706S

Signal generator

  • Six waveforms: sine, square, triangle, half sine, positive sine and sawtooth
  • Digit-by-digit frequency entry; duty cycle for square
  • Keeps running in the background while you use the oscilloscope or the multimeter
  • Output is OFF after power-on by default, or restores its last state (Settings → Device → Power → Generator at startup)
  • Rearrangeable screen (Settings → Display → Generator layout)
  • ZT703S: square output as in the stock firmware (DAC below 1 kHz, PWM from 1 kHz) or PWM always; Reference 1 kHz preset
  • ZT706S: its external generator module, up to 10 MHz

USB and remote control

  • USBTMC and CDC (virtual COM port) with SCPI commands, working alongside the local UI
  • Compatible command profiles for Rigol DS oscilloscopes and the OWON XDM1041 multimeter, so existing PC software such as ngscopeclient can talk to the device
  • USB Remote mode: the PC controls the device while the screen keeps showing live data
  • USB data works only in the 200/100 performance profile. Connect directly to a PC port: disconnects are known, especially through USB hubs.

Interface and files

  • LVGL-based user interface (English only)
  • Rearrangeable screens: on the oscilloscope, choose the order of the waveform, the measurements and the soft-keys (Analyze → Layout); on the multimeter, the order of the reading, the statistics/bar/trend, the dial and the soft-keys (MENU → Layout). Soft-keys are at the bottom by default, in the same order as the physical F1–F4 keys
  • The labels above F1–F4 always show what each key does right now; in menus they stay at the bottom, right above the keys
  • Oscilloscope color schemes (Analyze → Colors): Current, High contrast, Daylight and Amber, plus custom RGB colors for individual elements. Multimeter looks: Custom and Hybrid
  • BMP screenshots with a built-in viewer
  • Settings and the color theme are stored as JSON files on the external SPI Flash and saved when you switch the device off, restart it or enter Recovery. The microcontroller's internal Flash holds only the firmware. You can edit the files from a computer; a damaged settings file is restored from its previous version or from a copy in /openosc/SETCOPY/.
  • Hold-to-power-off with a progress bar
  • Hardware watchdog in both the firmware and Recovery: a hang or a crash restarts the device

Recovery bootloader

  • Shows the device storage as a USB drive and installs firmware from /openosc/UPDATE/
  • Accepts .OSC packages and raw .bin images; verifies the board model and CRC before erasing
  • Shows the factory calibration data and its format (long or compact) and can save a copy of the factory Flash block
  • Checks and repairs the FAT file system, and can format the storage drive
  • Opens automatically if the main firmware is missing or invalid

How it works

The device's own factory bootloader occupies the first 128 KiB of internal Flash. OpenOSC never modifies it. OpenOSC is installed on top of it in two parts:

Part Address Purpose
Factory bootloader 0x08000000 Untouched, together with the calibration and factory settings stored in the same block. Accepts the stock .ZTK update containers.
OpenOSC Recovery 0x08020000 Second-stage bootloader (128 KiB). Exposes a USB drive and installs the main firmware.
OpenOSC firmware 0x08040400 The main application.

Installation

Installation takes two steps. First, the Recovery bootloader is installed through the device's standard firmware update mechanism. Then Recovery installs the OpenOSC firmware. The same steps, with more detail, are in the wiki: Installation and Updating.

Step 1: install the Recovery bootloader (standard update)

Recovery is packed as a regular factory update container (.ZTK):

  • ZT703S: OpenOSC-Recovery-ZT703S.ZTK
  • ZT706S: OpenOSC-Recovery-ZT706S.ZTK

The bootloader reads the target model from the file header. On most units the file name can be changed, as long as it keeps the upper-case .ZTK extension.

Important

If Recovery does not install (the file disappears from the drive, but the stock application still starts), rename the file to ZOYI-703S-FW-V143.ZTK and copy it again. Some ZT703S units (Boot v1.0.15) install only files with this kind of name (#16).

If a large .ZTK does not fit on the drive ("not enough free space"), free up the device's storage or format it from the stock application: Scope → MENU → Apps → Image Viewer → F1 → Format (F3).

Install it the same way as an official firmware update:

  1. Put the device into the factory USB update mode and connect it to a computer.
  2. Copy the .ZTK file for your model into the firmware folder on the drive that appears.
  3. Wait until the bootloader finishes. It installs the file and deletes it from the drive.
  4. The device restarts into OpenOSC Recovery; restart it manually if it does not. The stock application has been replaced, so Recovery opens its menu.

Optional: back up the factory block

This step is optional. You can skip it and go straight to step 2.

OpenOSC never writes to the factory block. The only Flash write code in OpenOSC accepts addresses from 0x08040000 upward, the firmware area, so neither Recovery nor the firmware can erase or change the factory block, even by mistake. Installing, updating and running OpenOSC leave it exactly as it was.

The backup is a precaution for rare events outside OpenOSC, such as a hardware fault. If you want one:

  1. In Recovery, select BACKUP FACTORY BOOT, then CONFIRM and press MENU.
  2. Recovery copies the whole factory block (0x08000000–0x0801FFFF, 128 KiB) to the USB drive and verifies the copy:
    • /openosc/BACKUP/FACTORY_BOOT_08000000.bin: the backup itself;
    • /openosc/BACKUP/FACTORY_BOOT_08000000.txt: its address, size and CRC32.
  3. Copy both files from the USB drive to your computer and keep them somewhere safe.

The block contains the factory bootloader and this unit's own calibration and settings. Keep a separate backup for each device and never write one device's backup to another. Writing a backup back requires an SWD programmer.

Step 2: install the OpenOSC firmware (through Recovery)

  1. Start Recovery. It opens automatically when no valid firmware is installed. Later, you can open it by holding F2 while the device starts.
  2. Connect the device to a computer. Recovery shows the device's storage as a USB drive.
  3. Copy the firmware file for your model into /openosc/UPDATE/: OpenOSC-Firmware-ZT703S.OSC or OpenOSC-Firmware-ZT706S.OSC (from the release or your own build).
  4. Finish copying. Optionally, eject the drive on the computer.
  5. On the device, select UPDATE FIRMWARE, choose the file, select CONFIRM and press MENU.
  6. When the update completes, select START APPLICATION.

Recovery controls: MENU = OK, F4 = back/cancel, arrow keys = navigation. Every confirmation starts on CANCEL: press left/right to select CONFIRM, then MENU. If the computer still has the USB drive mounted, Recovery first asks DISCONNECT USB DISK?. Confirm it and Recovery detaches the drive itself; the cable can stay connected.

Recovery checks the board model, CRC and vector table of the image before erasing anything. An image for another model is rejected. Later updates of the main firmware use step 2 only.

Going back to the stock firmware

You can return to the stock firmware at any time. OpenOSC only replaces the application area. The factory bootloader is never modified, and it starts before OpenOSC every time the device is switched on.

  1. Get the official firmware update (.ZTK) for your model from the manufacturer. It is a good idea to download it before you install OpenOSC.
  2. Install it exactly like step 1: put the device into the factory USB update mode and copy the file into the firmware folder.
  3. The factory bootloader replaces OpenOSC Recovery and the OpenOSC firmware with the stock application.

The calibration and the factory settings are stored in the factory block, which OpenOSC never writes, so the stock firmware uses them as before. OpenOSC's own files in the /openosc/ folder on the storage drive are not needed by the stock firmware and can be deleted.

The factory block backup is not needed for this. It is a safety copy for the unlikely case that the block itself is ever damaged.

Building

Requirements: PlatformIO. The ST platform and the ARM toolchain are pinned in platformio.ini and installed automatically.

pio run

This builds both devices. Output files:

Device Recovery (step 1) Firmware (step 2)
ZT703S .pio/build/recovery/OpenOSC-Recovery-ZT703S.ZTK .pio/build/firmware/OpenOSC-Firmware-ZT703S.OSC
ZT706S .pio/build/zt706s_recovery/OpenOSC-Recovery-ZT706S.ZTK .pio/build/zt706s_firmware/OpenOSC-Firmware-ZT706S.OSC

Each build folder also contains firmware.bin. For the firmware environments, this .bin has a board marker and Recovery accepts it as well. To build one device only, run, for example, pio run -e recovery -e firmware for ZT703S.

The firmware version is taken from VERSION.

Third-party components

All dependencies are included in vendor/:

  • STM32CubeH7: CMSIS, HAL and USB Device library (ST)
  • CMSIS-DSP (Arm, Apache-2.0)
  • FatFs (ChaN)
  • LVGL 9.6.0 (MIT)
  • ArduinoJson 6.21.5 (MIT)
  • IBM Plex Sans and Noto Sans Mono fonts (SIL OFL 1.1)

Each component keeps its own license file.

Contributing

Bug reports, ZT706S test results and pull requests are welcome. See CONTRIBUTING.md and the Code of Conduct. Questions go to Discussions; security problems are reported as described in SECURITY.md.

For the code base, see the contributor pages in the wiki: Building, Architecture Overview, Source Layout and Memory and Flash Layout.

License

OpenOSC is licensed under the GNU General Public License v3.0.

All product names and trademarks belong to their respective owners. This project is not affiliated with or endorsed by the device manufacturer.

Support the project

If OpenOSC is useful to you, you can support its development:

Releases

Releases come out often, and you do not need to install every one: see Why are there so many releases? in the FAQ.

About

Open-source oscilloscope, multimeter and signal generator firmware for ZT703S / ZT706S handheld scopemeters (STM32H7B0)

Resources

Code of conduct

Contributing

Security policy

Stars

0 stars

Watchers

0 watching

Forks

Releases

Packages

Contributors

Languages