Scope: Software Voltage Scaling (V/Div) in Oscilloscope Mode #174

Not planned

Description

@OlegMedvedcuk

One request

  • This request describes one feature or improvement, or changes that belong to the same feature.

Area

Scope

What do you want to do?

In oscilloscope mode, provide the ability to digitally zoom the vertical voltage scale (Zoom) and adjust the voltage sensitivity per division to 1 mV, 2 mV, 5 mV, and 10 mV/div. This will allow weak signals to be displayed at a larger scale, improving the accuracy of their visual analysis and measurement.
Implement this functionality similarly to the existing time-axis zoom (Time/Div), with convenient switching between voltage scales (V/Div).

IMG_20261126_173403 IMG_20261126_173017 IMG_20261126_173158

Proposed solution

No response

Alternatives

No response

Devices

  • ZT703S
  • ZT706S

Activity

  1. added
    enhancement
    on Nov 26, 2026
  2. changed the title [-]Software Voltage Scaling (V/Div) in Oscilloscope Mode.[/-] [+]Scope: Software Voltage Scaling (V/Div) in Oscilloscope Mode[/+] on Nov 26, 2026
  3. TzOk83 commented on Nov 26, 2026

    @TzOk83

    Digital zoom on the voltage axis will basically display random noise. This scope already goes to the limits (or even beyond) of its ADC.

  4. OlegMedvedcuk commented on Nov 26, 2026

    @OlegMedvedcuk
    Author

    The DM40 has already been implemented and works very well. At least, we have the opportunity to give it a try and see for ourselves how well it performs.

  5. bve commented on Nov 26, 2026

    @bve
    Owner

    Thanks for the request and the photos. I'm closing this because of hardware limits.

    The ZT703S and ZT706S front end goes down to 20 mV/div, and the ADC is 8-bit. A 1, 2, 5 or 10 mV/div scale could only stretch the codes already captured at 20 mV/div. Each division would hold just a few ADC steps, so the trace would show quantization steps and front-end noise, not more detail of the signal (as TzOk83 noted above). The DM40 has a different analog front end and ADC, so its results don't carry over to these units.

    For weak signals, the best options on these devices are the 20 mV/div range with DC or AC coupling as appropriate, Average acquisition for repetitive signals, and the Record readouts basis, which measures over every point of the record.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    enhancement

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions