I would like to suggest a more intuitive and engineer-friendly automatic unit formatting for resistance and capacitance measurements.
Currently, some readings are displayed using unnecessarily large prefixes or small decimal values. While mathematically correct, this is not always the most convenient representation when working with real electronic components.
Examples:
0.670 MΩ → 670 kΩ
0.090 nF → 90 pF
22 mF → 22000 µF
The goal is to display measurements in the units most commonly used by electronics engineers, making readings easier to understand and compare directly with component markings, datasheets and schematics.
Proposed solution
Implement more human-friendly automatic unit selection with the following preferred display ranges:
- Resistance
0–999.99 Ω → display in Ω
1–999.99 kΩ → display in kΩ
1–999.99 MΩ → display in MΩ
For example, display 670 kΩ instead of 0.670 MΩ.
- Capacitance
Below 1 nF → display in pF
From 1 nF to below 1 µF → display in nF
From 1 µF upwards → display in µF, including millifarad-range measurements.
Examples:
0.090 nF → 90 pF
0.470 µF → 470 nF
22 mF → 22000 µF
The displayed precision should follow the actual measurement resolution. Unit conversion should not imply additional measurement accuracy.
Benefits
More intuitive readings, especially for beginners and electronics hobbyists.
Matches the units commonly encountered on electronic components, datasheets and schematics.
Reduces mental unit conversions when diagnosing and repairing circuits.
Makes measurements easier to compare with nominal component values.
Avoids unnecessarily small decimal readings when a more familiar unit is available.
Standards and references
This suggestion is inspired by the recommendations in NIST SP 811, Section 7.9 — Choosing SI prefixes.
NIST recommends choosing prefixes that keep numerical values between 0.1 and 1000 whenever practical, while also considering ease of understanding and established practices in a particular field of technology.
Importantly, NIST explicitly states that this is a recommendation, not a mandatory requirement. The proposed capacitance formatting intentionally prioritizes common electronics industry practice (µF for larger capacitors).
References:
NIST SP 811, Section 7.9: https://www.nist.gov/pml/special-publication-811/nist-guide-si-chapter-7-rules-and-style-conventions-expressing-values
BIPM — SI prefixes: https://www.bipm.org/en/measurement-units/si-prefixes/
Alternatives
No response
Devices
- ZT703S
- ZT706S
Activity
bve commentedon Nov 26, 2026
Included in the OpenOSC 0.22.0 pre-release.
The multimeter now selects resistance and capacitance prefixes based on magnitude and measurement resolution, including on the analog screen and in REL and statistics. For example, 0.6700 MΩ displays as 670.0 kΩ and 0.090 nF as 90 pF.