DMM: Improve resistance and capacitance unit formatting #168

Done

Description

@extrimexxx

One request

  • This request describes one feature or improvement, or changes that belong to the same feature.

Area

DMM

What do you want to do?

I would like to suggest a more intuitive and engineer-friendly automatic unit formatting for resistance and capacitance measurements.

Currently, some readings are displayed using unnecessarily large prefixes or small decimal values. While mathematically correct, this is not always the most convenient representation when working with real electronic components.

Examples:
0.670 MΩ → 670 kΩ
0.090 nF → 90 pF
22 mF → 22000 µF

The goal is to display measurements in the units most commonly used by electronics engineers, making readings easier to understand and compare directly with component markings, datasheets and schematics.

Proposed solution

Implement more human-friendly automatic unit selection with the following preferred display ranges:

  1. Resistance
    0–999.99 Ω → display in Ω
    1–999.99 kΩ → display in kΩ
    1–999.99 MΩ → display in MΩ

For example, display 670 kΩ instead of 0.670 MΩ.

  1. Capacitance
    Below 1 nF → display in pF
    From 1 nF to below 1 µF → display in nF
    From 1 µF upwards → display in µF, including millifarad-range measurements.

Examples:
0.090 nF → 90 pF
0.470 µF → 470 nF
22 mF → 22000 µF

The displayed precision should follow the actual measurement resolution. Unit conversion should not imply additional measurement accuracy.

Benefits
More intuitive readings, especially for beginners and electronics hobbyists.
Matches the units commonly encountered on electronic components, datasheets and schematics.
Reduces mental unit conversions when diagnosing and repairing circuits.
Makes measurements easier to compare with nominal component values.
Avoids unnecessarily small decimal readings when a more familiar unit is available.

Standards and references
This suggestion is inspired by the recommendations in NIST SP 811, Section 7.9 — Choosing SI prefixes.
NIST recommends choosing prefixes that keep numerical values between 0.1 and 1000 whenever practical, while also considering ease of understanding and established practices in a particular field of technology.
Importantly, NIST explicitly states that this is a recommendation, not a mandatory requirement. The proposed capacitance formatting intentionally prioritizes common electronics industry practice (µF for larger capacitors).

References:
NIST SP 811, Section 7.9: https://www.nist.gov/pml/special-publication-811/nist-guide-si-chapter-7-rules-and-style-conventions-expressing-values
BIPM — SI prefixes: https://www.bipm.org/en/measurement-units/si-prefixes/

Alternatives

No response

Devices

  • ZT703S
  • ZT706S

Activity

  1. added
    enhancement
    on Nov 26, 2026
  2. bve commented on Nov 26, 2026

    @bve
    Owner

    Included in the OpenOSC 0.22.0 pre-release.

    The multimeter now selects resistance and capacitance prefixes based on magnitude and measurement resolution, including on the analog screen and in REL and statistics. For example, 0.6700 MΩ displays as 670.0 kΩ and 0.090 nF as 90 pF.

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment

Metadata

Metadata

Assignees

No one assigned

    Labels

    enhancement

    Type

    No type

    Projects

    No projects

      Milestone

      No milestone

      Relationships

      None yet

      Development

      No branches or pull requests

      Issue actions