pulse < 130 is very high #9

Description

@FireDeveloper

RMT starts counting from first high pulse. This results in measuring the time of Treh and Tlow of bit 39.
https://files.seeedstudio.com/wiki/Grove-Temperature_and_Humidity_Sensor_Pro/res/AM2302-EN.pdf
DS1Z_QuickPrint1 - Copy

The reason that it works is because the DHT has a low pulse after bit0 (Ten) which happens to have the same width with Tlow and rmt counts it as bit0.
chrome_RuhvtQPJ8Y

According to the datasheet the minimum width of the measured pulses here https://github.com/bertmelis/esp32DHT/blob/master/src/esp32DHT.cpp#L135 is 123us and the average 130us (exactly the limit)

Also an improvement would be here https://github.com/bertmelis/esp32DHT/blob/master/src/esp32DHT.cpp#L144 to change to
data[i].duration0 + data[i-1].duration1;