Repository navigation
[qec] Share Stim measure-line emission in the emitter module #540
New issue
Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.
By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.
Already on GitHub? Sign in to your account
Merged
Merged
Changes from all commits
Commits
File filter
Filter by extension
Conversations
Failed to load comments.
Loading
Jump to
Jump to file
Failed to load files.
Loading
Diff view
Diff view
There are no files selected for viewing
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
This file contains hidden or bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Oops, something went wrong.
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
There was a problem hiding this comment.
Choose a reason for hiding this comment
The reason will be displayed to describe this comment to others. Learn more.
Approve. I would merge this slice on b3d6572.
Both builders call
stim_emit::emit_measure_linefor{op} id id\n. The helper keeps caller order and does not skip an empty list. Single-block memory still choosesMZorMXfrom the measure basis, then passes that op. Lattice surgery still passesMZ. Its record counter stays in the builder: after the line,rec_countincreases bydata_atoms.len(), the same total as the old per-id increments. An empty lattice window stillcontinues before the call.Closing detectors stay in the single-block builder, after this line. The checked-in Stim gold is not in the diff. The new function has no
unwraporexpect.measure_line_keeps_caller_orderlocksMZ 4 0 4and an emptyMXline.Title, body, and the commit mention the issue only as
Refs #473. They do not use fixes/closes/resolves, and they do not say the issue stays open. This slice does not move closing detectors.