Air mass consumption #45

Description

@BartgeierXC

Hi,

I just realized that the air compressor's power consumption seems off in the PolarizeFuelCellStack example. It turns out that the air mass provided by the compressor doesn't match the consumption of the fuel cell stack. For example, by calculating the air mass for the 450 cell stack @450 A via N *I * M_air/(4 * F * x_O2_Air) at a stoichiometry of 1, the provided dry air mass should be around 72 g/s whereas the compressor in your example only provides around 14 g/s. Can you please explain the formula you use in SubSystemAirControl.setAirMassFlow?