Heliograph

A heliograph signalled messages with sunlight. This one translates what your solar inverter is saying into languages the rest of your network speaks.

Latest release CI status MIT license Runs on ESP32-S3

Your solar inverter, finally yours. Whether it is fifteen years old and abandoned by its manufacturer or fresh out of the box, Heliograph is open-source firmware for a small, cheap box that sits next to it and speaks its native protocol. It reads the inverter and hands the data to whatever you already use — Home Assistant, MQTT, Modbus TCP, a REST/JSON API, or Prometheus — and on the relay boards it can also turn the inverter down when you want it to produce less. New Modbus inverters go in as a TOML data file — no C++, no firmware fork. It runs entirely on your own network. No account, no cloud, no subscription.

⚡ Flash it from your browser — nothing to install →

Heliograph's built-in web dashboard showing live production from a long-unsupported EverSolar inverter
The built-in dashboard — a long-unsupported EverSolar read live over RS485, with no cloud and no app in between.


The problem

Solar inverters are built to last twenty years. The software around them is not.

  • The manufacturer's monitoring died. The portal was shut down, the app stopped working, or the monitoring dongle is no longer supported. The inverter still produces perfectly — you just cannot see it any more. Heliograph exists because of an EverSolar that outlived its own monitoring portal.
  • Your data goes to their cloud first. Production figures from equipment in your own home travel to a manufacturer's server, come back minutes later, and vanish when your internet does. You cannot query yesterday's output without asking someone else's website.
  • It does not talk to anything you own. No MQTT, no Modbus, no API — so the numbers never reach Home Assistant, your dashboards, or your own monitoring.
  • You cannot turn it down when you need to. With negative electricity prices or a feed-in limit, you may want the inverter to produce less. Most consumer inverters offer no way to do that locally.

Heliograph addresses the first three for the inverters it supports, and the fourth on the relay boards (see Curtailment).

What it does

It reads your inverter

Heliograph speaks your inverter's native protocol over RS485, converts everything into one common set of measurements, and republishes that.

Four words that appear throughout this page. You do not need to understand them to follow the setup, but they stop being mysterious once someone says them plainly:

  • RS485 — a two-wire electrical standard for sending data over a long cable, used by nearly every inverter's communication port. It is wiring, not software: two data wires and a ground, and several devices may share one pair.
  • Modbus RTU — the most common language spoken over those wires. "RTU" here just means the serial-cable flavour. Not to be confused with Modbus TCP, which is the same language over your network, and is one of the things Heliograph offers to your own tooling. Your inverter side is RTU; the port-502 side is TCP. They are not the same wires.
  • Unit id — the number that identifies one device on a shared RS485 cable, so that two inverters on one pair can be told apart. Most ship as 1; some vendors ship something else, and the table below says so where it matters.
  • MPPTmaximum power point tracker: one of the inverter's independent solar inputs. An inverter with two MPPTs has two strings of panels it optimises separately, which is why readings come per tracker.
flowchart LR
    INV["☀️ Your inverter<br><i>any age, any brand<br>this project supports</i>"]
    subgraph home["Your own network — no account, no cloud, no subscription"]
        direction TB
        BR["<b>Heliograph</b><br>ESP32-S3 + RS485<br><i>a small box next to the inverter</i>"]
        HA["🏠 Home Assistant"]
        TOOLS["📊 Grafana · Prometheus<br>Node-RED · your own scripts"]
    end
    INV -- "RS485<br>two data wires + ground" --> BR
    BR -- "MQTT auto-discovery<br>entities appear by themselves" --> HA
    BR -- "Modbus TCP · REST/JSON · /metrics" --> TOOLS
    style BR fill:#e8f4ea,stroke:#2d7a3e,stroke-width:2px
    style INV fill:#fff8e1,stroke:#b8860b
Loading

Everything in that box stays in your house. The inverter's own cloud, if it still has one, is not in the picture — and neither is ours, because there isn't one.

Where it puts the data:

Integration How
Home Assistant MQTT with auto-discovery — entities appear on their own
MQTT Any broker, your own topics
Modbus TCP Port 502, for building/industrial tooling
REST / JSON /api/v1/ — see docs/rest-api.md
Prometheus /metrics — see docs/prometheus.md; also readable by Zabbix and Checkmk
Web dashboard Built into the device; works with no internet at all

The Inverters tab listing each inverter's identity, capabilities and every live measurement
Everything the inverter reports collapses into one canonical model — which is why the same values reach Home Assistant, MQTT, Modbus, REST and Prometheus without any per-output glue.

And it can turn your inverter down

On the relay boards, Heliograph drives the DRM input that many inverters carry — the demand-response terminals an energy company would otherwise use — so you can cut or step down production during negative electricity prices or under a feed-in limit. You control it from Home Assistant, MQTT or the API, like any other switch.

This matters most precisely where the reading side is limited: for an inverter that exposes no way to write a power limit over RS485, a DRM contact is often the only control path that exists. It is the one thing here that acts rather than observes, so it ships switched off, behind two independent gates, and fails safe by design — details in Curtailment.

And you can teach it a new inverter

Most Modbus inverters can be added without touching C++. A driver is a TOML file listing the registers and their scaling, compiled into the firmware at build time — if you can read the register table in your inverter's manual, you can write one. Every integration above then works for it for free, because outputs only ever see the canonical measurements, never the raw protocol. There is even a probe script for reading a device you have in front of you.

Full walkthrough: docs/adding-a-device.md.


Which inverters work today?

Start here — this is the question that decides whether the rest is worth your time. One inverter family is in daily production use; several more are implemented and waiting for their first real-world confirmation. And if yours is not on the list yet, you are not stuck: adding a Modbus inverter is a data file, not a code change (see Help support your own inverter). The honest, per-family picture:

Inverter family Connection Status
EverSolar / Zeversolar legacy (TL series) RS485 Stable — the only driver at this level. Running in production and validated over eight consecutive unassisted sunrises, the transition where its one known bug lived. Several inverters on one loop are supported but not yet confirmed on hardware — read the pitfalls first, and report what happens on #82
Growatt SPH hybrid (3–6 kW) Modbus RTU over RS485 Experimental — register map transcribed from documentation, not yet confirmed against real hardware
Growatt MIC TL-X (0.6–3.3 kW, single phase) Modbus RTU over RS485 Experimental — map cross-checked against two independent sources that agree, not yet confirmed against real hardware; see docs/growatt-mic-tl-x-protocol.md
Growatt MIN TL-X (2.5–6 kW, single phase) Modbus RTU over RS485 Experimental — same register layout as the MIC, with a second PV string; separate profile because the tracker count differs. Not yet confirmed against real hardware; see docs/growatt-mic-tl-x-protocol.md
Deye / Sunsynk SUN-xK-SG hybrid (single phase) Modbus RTU over RS485 Experimental — every mapped row corroborated by two independent implementations that agree, not yet confirmed against real hardware. Battery power, grid frequency and inverter temperature are deliberately not published until a bench session settles them; see docs/deye-sun-xk-sg-protocol.md
Solis / Ginlong RHI hybrid (3–6 kW, single phase) Modbus RTU over RS485 Experimental — every mapped row corroborated by two independent implementations that agree, not yet confirmed against real hardware. Battery power needs a direction register this schema cannot combine, and the two sources disagree on meter power by a factor of 1000, so neither is published; see docs/solis-rhi-protocol.md
Sungrow SH residential hybrid Modbus RTU over RS485 Experimental, and the best-sourced map here — rows come from Sungrow's own protocol specification, cross-checked register by register against a widely deployed integration. Not yet confirmed against real hardware; see docs/sungrow-sh-protocol.md
Huawei SUN2000 (residential, ± LUNA2000) Modbus RTU over RS485 Experimental, single-sourced — transcribed from one mature library implementing Huawei's published interface, not cross-checked against the vendor document itself. Not SunSpec. See docs/huawei-sun2000-protocol.md
GoodWe ET / EH / BT / BH hybrid Modbus RTU over RS485 Experimental, single-sourced, read-only — the public vendor protocol document is titled "Read Only", so no setpoints are declared at all. Set unit_id to 247: GoodWe ships this family at 247, not 1, and a wrong address looks exactly like a wiring fault. See docs/goodwe-et-protocol.md
SolaX X1 series (X1 Mini G1/G2/G3) RS485 Experimental — the first attempt on real hardware (an X1-Mini-G1) returned no data at all. Read docs/solax-x1-protocol.md before you buy or wire anything
Sofar Solar HYD 3…6K-EP (single phase, hybrid) Modbus RTU over RS485 Experimental, but two-sourced — sixteen of its twenty registers agreed by the vendor protocol document and an independent configuration published as working on a real HYD-3600-EP; the energy counters, grid power and house load are vendor-only. Grid power is mapped with a negative scale — the vendor counts export positive where we count import positive. See docs/sofar-hyd-protocol.md
Sofar Solar HYD 5…20K-3PH (three phase, hybrid) Modbus RTU over RS485 Experimental — shares the EP map and adds phases L2/L3. Most of what it shares is two-sourced; eight rows are vendor-document only — the four L2/L3 registers, both energy counters, grid power and house load — the phases because the hardware behind the second source is single-phase. See docs/sofar-hyd-protocol.md
SolarMax (S / C / MT / TS series) RS485 (MaxTalk, not Modbus) Experimental — the vendor went bankrupt and took its portal with it, so this is the only way these units report anything. Framing agreed by two independent sources; several scale factors rest on one, and DC voltage is deliberately not published because the two disagree. No SolarMax has ever answered this driver — see docs/solarmax-protocol.md
Any inverter implementing SunSpec Modbus RTU over RS485 Experimental — one generic driver for the published standard, so no per-vendor file is needed. Not yet confirmed against any physical device; see docs/sunspec.md for which vendors are worth trying

What the labels mean, weakest first:

  • Experimental — the protocol has been implemented from documentation, but nobody has confirmed it against that inverter yet. It may simply not work. You would be the first.
  • Beta — confirmed against a real inverter, running, still collecting evidence before being called Stable. Nothing sits here today.
  • Stable — validated and soak-tested on real hardware over a long enough run to trust it unattended. One driver has reached this.

The same three words apply to the register map you pick, separately from the driver that reads it. One driver serves every Modbus inverter here, so its label can only ever describe the least-proven map in the build — the map's own status is shown next to it when you choose one, and in the coverage matrix. Every Modbus map here is Experimental, including those for inverters this project has running: what has been proven there is the plumbing, not the register table.

Two more things to check on your own inverter:

  1. Does it have an accessible communication port? Usually a screw terminal marked RS485/COM, or an RJ45 socket. It must be reachable from outside — you should never need to open the inverter.
  2. Is that port free? If a manufacturer's WiFi dongle is plugged into the port you need, it may have to come out. On some models the dongle sits on a separate port and both can stay; on others it does not.

Not in the table? That does not have to be the end of it — see Help support your own inverter. Adding a Modbus inverter is a data file, not programming.


Before you start: what you are getting into

Read this properly. Heliograph is a do-it-yourself project.

  • You will be connecting two or three wires to your inverter's communication port. That is low-voltage data wiring — not mains, and not the DC side of your panels.
  • Everything described here uses external ports only. You should never open the inverter's enclosure. If a guide ever tells you to, stop.
  • Your inverter is still equipment connected to the grid. If you are not comfortable working around it, ask a qualified installer. There is no shame in that, and it is far cheaper than the alternative.
  • Always follow your inverter's own manual for what its connector pins do. Pinouts differ between models and even between generations of the same model. Never assume.
  • Interfering with a communication port can, on some models, affect warranty or the manufacturer's monitoring. Check before you commit.
  • Heliograph is provided under the MIT licence: no warranty, at your own risk. It only ever reads your inverter unless you deliberately enable the relay features described below.

Getting started

1. Get the hardware

You need one ESP32-S3 board with an RS485 port. Pick based on whether you also want curtailment:

Board What it adds Status
Waveshare ESP32-S3-RS485-CAN battery-backed clock; the reference board Production — pick this if you only need to read the inverter
Waveshare ESP32-S3-Relay-1CH 1 relay (on/off curtailment), clock Hardware-verified — boots and actuates its relay on real hardware 2026-07-26; polarity not yet meter-measured
Waveshare ESP32-S3-Relay-6CH 6 relays (stepped curtailment), status LED, buzzer Hardware-verified — relays, polarity and failsafe measured 2026-07-23

Besides the board you need a USB-C cable, and wire for the RS485 connection: two data conductors (A and B) plus a ground reference. A cut Ethernet patch cable is often the easiest source, and for inverters with an RJ45 communication port it may be all you need. The RS485-CAN and Relay-6CH can be powered either over USB-C or from a 7–36 V DC screw terminal, which is handy when there is no USB power near the inverter; check the product page for whichever board you buy.

For one inverter, A/B/GND is genuinely all there is to it.

Several inverters share one cable. They hang off it in a chain — not one cable each — and each answers to its own address:

flowchart LR
    B["🔌 Bridge<br><b>bus end</b><br>120 Ω ON"]
    I1["Inverter<br>address 1<br>termination OFF"]
    I2["Inverter<br>address 2<br>termination OFF"]
    I3["Inverter<br>address 3<br><b>bus end</b><br>120 Ω ON"]
    B --- I1 --- I2 --- I3
    style B fill:#e8f4ea,stroke:#2d7a3e,stroke-width:2px
    style I3 fill:#e8f4ea,stroke:#2d7a3e,stroke-width:2px
Loading

Three rules in one picture: chain, not star; the 120 Ω terminator goes at the two ends only; and every unit needs its own address set before you connect them, or two inverters answer at once and their replies collide. Read docs/rs485-bus.md before you wire it — including what a star topology looks like and why it works on the bench and fails in the roof.

Several inverters on one bus are polled in turn, up to eight, each with its own address. The first is configured under Settings → Driver, the rest under Settings → Extra devices — one row per inverter, each with its own driver and whatever that driver needs to address it. The page refuses to save a row with no driver, an unset register map, or an address already in use, because all three are mistakes the firmware can only report as a log line at boot. Save, then restart. Afterwards the Device tab lists every inverter that is actually being polled, and says so plainly when one of the configured ones is missing and why.

Over the API it is one field, and sending the array replaces it:

curl -u admin:PASSWORD -X PATCH http://<bridge>/api/v1/config \
  -H 'Content-Type: application/json' \
  -d '{"additional_devices":[{"driver_id":"modbus_profile","options":{"unit_id":"2"}}]}'

Extended discovery sweeps addresses 1–8, so the wizard reports one candidate per inverter with the address each answered at — use it to check that the addresses you assigned actually took. It configures one device; the rest go in additional_devices as above. Quick discovery is unchanged: each driver's default address only.

Every output carries all of them now. Modbus TCP serves one unit id per inverter, consecutively from modbus.unit_id — unit 1, 2, 3 with the default — and the register map is the same at each. Prometheus labels every inverter series with device="…", the same id REST and Home Assistant use. Note that the units share one bus and one poll interval, so each is read roughly every N intervals with N inverters.

2. Flash the firmware

  • In your browser (easiest): open the web installer in Chrome or Edge, plug the board into your computer with USB-C, pick your board, click Connect. Nothing to install.

  • With esptool: download heliograph-<version>-<board>-factory.bin from the latest release:

    esptool.py --chip esp32s3 write_flash 0x0 heliograph-<version>-<board>-factory.bin
  • From source: pio run -e waveshare-rs485-can (or the environment for your board), then flash .pio/build/waveshare-rs485-can/firmware.factory.bin.

Already running Heliograph? Update over the air instead — Settings → Firmware update with the release's heliograph-<version>-<board>.bin. Settings survive an over-the-air update; a factory flash erases them.

3. Connect it to your WiFi

On first boot the board creates its own WiFi network called Heliograph-Setup-XXXX. Join it with your phone or laptop; the setup page opens by itself. Choose your network, set an admin password, and save. The board reboots and tells you the address to visit, something like http://heliograph-a1b2c3.local.

Write that admin password down. The same setup network comes back on its own if the board later loses WiFi for a few minutes — a router reboot is enough — so that you can point it at a new network without digging the board out. Because that network is open and anyone in range could otherwise reconfigure your bridge, changing anything through it asks for the admin password once one is set.

If you lose the password, the way back in is a factory reset: hold the board's BOOT button for about 5 seconds while it is running. That erases the stored configuration — WiFi, password, everything — and returns the board to first-boot setup. Failing that, re-flash a -factory.bin over USB, which wipes the same settings.

Two things worth knowing before you rely on it. On the Relay-6CH the countdown blinks the LED and the buzzer confirms the wipe; on the RS485-CAN there is no LED and no buzzer, so the hold gives no feedback at all — the board simply reboots into setup when it worked. And the reset itself is only hardware-verified on the Relay-6CH; on the other two boards the pin comes from the schematic and nobody has run it. Details and the download-mode caveat: docs/hardware.md.

4. Wire it to the inverter

With the inverter's manual in front of you, connect:

  • board A → inverter A (sometimes labelled D+)
  • board B → inverter B (sometimes labelled D−)
  • board GND → inverter GND

Connect the ground. It is not optional folklore: without a shared reference the bus can stay completely silent no matter how the data wires are arranged. And if nothing comes through at first, swapping A and B is the single most common fix — it cannot damage anything.

5. Find your inverter

Open the dashboard and run the wizard on the Discovery tab. It tries the supported protocols and proposes a driver. It identifies the protocol, not the model — so a driver that ships several register maps still needs the map chosen, and the wizard's confirm step asks for it.

The wizard offers two modes. Quick tries each driver at its own default address, which is what you want for one inverter. Extended additionally sweeps addresses 1–8, which is slower and is how you check that the addresses you assigned to several inverters actually took.

If nothing answers, work down this list — the first two fix most cases:

  1. Swap A and B. It cannot damage anything, and reversed data wires are the single most common cause of complete silence.
  2. Check the ground wire is connected. Without a shared reference the bus can stay silent however the data wires are arranged.
  3. Unplug the manufacturer's dongle if one is on that port. Two masters on one bus corrupt each other's messages, and the dongle will not yield.
  4. Try the other baud rate. Most inverters ship at 9600; some at 115200. Discovery tries both, but a device configured to something else answers neither.
  5. Check the unit id. Most vendors ship 1 — GoodWe ships this family at 247, and a wrong address looks exactly like a wiring fault. Extended discovery finds it for you.
  6. Then turn the log level up to trace under Settings and watch the Logs tab. It shows exactly what is being sent and whether anything comes back, which separates "my wiring is wrong" from "it replied and we could not read it" — a distinction worth having before you open an issue.

The Discovery wizard stepping through interface, mode, probing, candidates, confirm, test poll and save
Discovery is a guided wizard: it probes the bus, proposes a driver, and lets you confirm with a test poll before anything is saved.

6. Connect your tooling

MQTT and Home Assistant discovery are configured under Settings; enable MQTT, point it at your broker, and the entities appear in Home Assistant by themselves. Modbus TCP listens on port 502, Prometheus scrapes /metrics, and the JSON API lives under /api/v1/.


Curtailment: turning the inverter down

The relay boards can drive an inverter's DRM input (the demand-response terminals many inverters carry) to reduce or stop production — useful during negative electricity prices or under a feed-in limit. This matters most for the inverters Heliograph can only read: if there is no way to write a power limit over RS485, a DRM contact may be the only control path that exists.

Three things are worth understanding before you consider it:

Status: the actuator is proven, the connection to an inverter is not yet. On the Relay-6CH the relays themselves have been verified on real hardware (2026-07-23): channel order, polarity, the power-cut failsafe and the de-energised boot state were all measured rather than assumed. The Relay-1CH's single relay has since been actuated on hardware too (2026-07-26), though its polarity and failsafe have not yet been meter-measured the way the 6CH's were. What has not happened yet on either board is driving a real inverter's DRM port — that step is waiting on a manufacturer's confirmation of how their terminals expect to be driven. Treat this as a capability that is built and bench-tested, not as one that has been run in the field.

It ships switched off. Two independent settings must both be changed before a relay can move (relays.enabled on, and security.read_only_mode off). A relay board with factory settings is inert.

Failing safe is a wiring decision. A de-energised relay leaves its NO contact open and its NC contact closed. Whichever way round your inverter expects its DRM input, one of those two contacts keeps the rule "if the bridge dies, the inverter keeps producing" true — without changing any firmware setting. On the 6CH this was measured, not assumed: cutting power releases the contact immediately, and the board boots with every relay de-energised. No relay state is stored anywhere, deliberately, so a reboot can never restore a curtailment nobody just asked for.

Full wiring rules and a pre-flight checklist: docs/drm.md. Check your own inverter's manual for what its DRM terminals expect — this varies by manufacturer and must never be guessed.


Help support your own inverter

If your inverter is not in the table, you are exactly the person this project needs. There are three ways to help, and only one of them involves writing code:

  1. Tell us it exists. Open a device request with the model and whatever documentation you have. Sometimes the protocol is already known.
  2. Add a Modbus inverter yourself — as a data file. Modbus devices are described by a TOML file listing registers and scaling, not by C++. If you can read a register table in a manual, you can write one. docs/adding-a-device.md walks through it, including a script for probing a device you have in front of you.
  3. Confirm an Experimental driver. The Growatt SPH and SolaX X1 drivers are implemented but unproven on real hardware. If you own one, running it and reporting what happened — including "it returned nothing" — is genuinely valuable. That is how the SolaX findings already in the docs came to be.

See CONTRIBUTING.md for the practicalities.


How it is built

A strict layering — Transport → Driver → canonical measurement model → output adapters — keeps brand-specific knowledge confined to src/drivers/<driver>/. Outputs only ever see canonical measurements and capabilities, which is why a new driver gets every integration for free. The protocol core is platform-independent and host-tested, so most of the firmware can be verified without any hardware. Unknown values are published as null or omitted, never zero — a missing reading must never look like a real measurement of nothing. Over-the-air updates are guarded by a watchdog-backed bootloader rollback that has already earned its keep in this project's own history.

Details: docs/architecture.md.

All the documentation

Thirty-three documents, and docs/README.md groups them by what you are trying to do — get it working, fix it when it does not, check whether your inverter is supported, connect your own tooling, add a new inverter, or understand how it is built. It also marks which documents are dated records rather than instructions, so nobody follows a "next step" that happened months ago.

Development

pio test -e native          # 1000+ host tests, no hardware needed
./tools/check_layering.sh   # architectural invariants
pio check -e native         # static analysis (cppcheck)
ruff check tools/           # lint for the Python tooling
pio run -e waveshare-rs485-can   # or -relay-1ch / -relay-6ch

The mock environment runs the full output stack against a simulated inverter — useful for UI and integration work without an RS485 bus. It adds two virtual relays and compiles the real drivers out; the driver itself is in every shipped image, so on real hardware you can just pick Mock Inverter under Settings → Driver.

It models a three-phase hybrid with two MPPTs and a battery — deliberately unlike any single real device, so an output adapter that quietly assumed one phase or no battery has something to fail against. Give each one a unit_id under Extra devices and you can run a whole simulated fleet: separate device ids, separate MQTT subtrees and Home Assistant devices, consecutive Modbus unit ids, and one device label per instance in Prometheus. Their solar curves are staggered, so they report different values at the same moment rather than one number multiplied by N — which is what makes a shared store or an off-by-one unit id visible instead of plausible.

What it cannot do is anything at the byte level: it ignores the transport entirely, so protocol framing, checksums and timing still need real hardware.

All inverter drivers are read-only, and that is not in tension with the curtailment above: no driver ever writes to your inverter over its protocol. Sending a setpoint would need a hardware-verified register map and a write row marked verified, and no shipped profile has one (see docs/device-profiles/schema.md for how write support is staged). Curtailment works the other way round — a potential-free contact on the bridge closing a circuit the inverter already offers for exactly that purpose, with no protocol write at all.

License

MIT — see LICENSE. Protocol knowledge was re-implemented from community references; credits and third-party licences in LICENSE-THIRD-PARTY.md.

About

ESP32 firmware that autodiscovers solar inverters over their native RS485 protocols and republishes them as MQTT/Home Assistant, Modbus TCP, REST and Prometheus