Rockwell ACD Project File Tools

The Rockwell .ACD file is an archive that contains all the files used by RSLogix / Studio 5000 Logix Designer. It consists of version text files, compressed XML metadata, and several proprietary binary database files (Comps.Dat, SbRegion.Dat, Comments.Dat, Nameless.Dat).

This library parses those binary databases and exposes the project contents — controller tags, programs, ladder rungs, data types (UDTs), add-on instructions (AOIs), and hardware modules — as Python objects. It can also serialise the parsed project to an L5X XML file that Studio 5000 can import.

Compatibility — Tested against Studio 5000 firmware versions 20–35. Python 3.8+ is supported; Python 3.12+ is recommended.


Installing

pip install acd-tools

Quick start — read an ACD file

load_acd() extracts the ACD into a temporary directory (system temp, auto-deleted when the call returns — see "Low-level access via ExportL5x" below if you want the extracted files left on disk):

from acd.api import load_acd

project = load_acd("MyController.ACD")
controller = project.controller

# Basic controller info
print(controller.name)            # controller name
print(controller.serial_number)   # e.g. "16#AB12_3456"
print(controller.modified_date)

# Iterate controller-scoped tags and their initial values
for tag in controller.tags:
    print(f"  {tag.name}  ({tag.data_type})")
    if tag._initial_value is not None:
        print(f"    initial value: {tag._initial_value}")

# Walk programs -> routines -> ladder rungs
for program in controller.programs:
    print(f"\nProgram: {program.name}")
    for routine in program.routines:
        print(f"  Routine: {routine.name}  [{routine.type}]")
        for i, rung in enumerate(routine.rungs):
            comment = routine._rung_comments.get(i)
            print(f"    Rung {i}: {rung}" + (f"  // {comment}" if comment else ""))

# Inspect user-defined data types and their members
for udt in controller.data_types:
    member_names = [m.name for m in udt.members]
    print(f"UDT {udt.name}: {member_names}")

# Inspect add-on instructions
for aoi in controller.aois:
    print(f"AOI {aoi.name}: {len(aoi.routines)} routines, {len(aoi.tags)} params")

# Inspect hardware modules
for module in controller.modules:
    print(f"Module {module.name}: vendor={module.vendor_id} "
          f"type={module.product_type} code={module.product_code} slot={module.slot_no}")

Tag values (including UDT initial values)

Controller-scoped and program-scoped tags carry their initial values when the data table instance can be located in the binary database:

# Scalar tag
tag = controller.tags[0]
print(tag._initial_value)        # e.g. 42 or "Hello" or {"Member1": 1, "Member2": 0}

# Array tag
for tg in controller.tags:
    if tg.dimensions:
        arr = tg._initial_value   # list of values, one per element
        print(f"{tg.name}[0]: {arr[0] if arr else None}")

For UDT-typed tags the initial value is a dict (scalar) or list[dict] (array) keyed by member name. BOOL members are decoded from their packed bit position; nested UDTs and STRING members are handled recursively. This also applies to Rockwell "module-defined" types (e.g. an I/O module tag typed AB:1794_IB32:I:0) — since every DataType's member layout is read from the ACD's own type definitions, decoding works identically whether the struct is a user-created UDT or an implicit module type:

for tag in controller.io_tags:
    print(tag.name, tag.data_type, tag._initial_value)
    # e.g. Local:10:I AB:1756_DI:I:0 {'Fault': 0, 'Data': 15870}

Tag and per-element/per-bit descriptions

Whole-tag descriptions are available via the description property:

tag = controller.tags[0]
print(tag.description)   # e.g. "Bin Status" (multi-line text is word-wrapped to one line)

Per-element and per-bit comments (the same ones Studio 5000 shows as <Comment Operand="..."> entries in an L5X export) are available as (path, text) tuples on tag._comments, already resolved to full Studio 5000 addresses:

for path, text in tag._comments:
    if path:   # empty path == the tag-level description, already covered by .description
        print(f"{path}: {text}")

# e.g.:
#   HTV_BStatus_Status[10].11: Tally Package Accumulating
#   Local:10:I.Data.13: Grader 13' PE
#   IO074:I.Data[0].0: Tray 4 / Accumulation / Motor Aux.
#   SorterStatusToGradeScan.SorterFeedback.UsingScanSolution: Should Be 1 if...

These same per-element/per-bit comments are also emitted as a standalone <Comments> block in tag.to_xml() / L5X output (right after <Description>, before <Data>), matching a real Studio 5000 export — verified byte-exact (Operand="..." is the path above with the tag name stripped and upper-cased, e.g. Operand=".GAIN", Operand="[2,2,1].BFRLUG.Z5_SAWPATTERN.3"). This only covers regular controller/program-scoped <Tag> elements — per-bit comments on I/O module connections (<Module><Connections><Connection><InputTag>/<OutputTag><Comments>) are not yet emitted (see the note under "Convert ACD to L5X" below).

I/O module tags (name contains :) are also available separately via controller.io_tags, and alias tags via controller.alias_tags:

for tag in controller.io_tags:
    print(tag.name, tag.data_type)

for alias in controller.alias_tags:
    print(f"{alias.name} -> {alias.target}")

Convert ACD to L5X

Export the parsed project as an L5X XML file (importable by Studio 5000):

from acd.api import ConvertAcdToL5x

ConvertAcdToL5x("MyController.ACD", "MyController.L5X").extract()

The output is pretty-printed by default. Pass pretty_print=False for a compact single-line file:

ConvertAcdToL5x("MyController.ACD", "MyController.L5X", pretty_print=False).extract()

Note — The L5X serialisation captures tags, programs, routines, rungs (including rung-level <Comment>s), UDTs, and AOIs with their initial values, along with per-tag <Description> and <Comments> blocks. A whole-project structural comparison against a real, decades-old production Studio 5000 export found <Tag>, <Module>, <Routine>, <Program>, <Rung>, <Task>, <DataType>, and <AddOnInstructionDefinition> counts to be exact matches, and both tag-level <Comments> and rung-level <Comment> content checked comment-by-comment (not just counted) with zero mismatches. The only two known, fully-understood remaining gaps: hardware module metadata (catalog numbers, connection parameters) is not fully round-tripped because Rockwell stores those as opaque CIP identity records rather than as strings, and per-bit comments/descriptions on I/O module connections (<Module><Connections><Connection><InputTag>/<OutputTag><Comments>) are not yet emitted — see CLAUDE.md's "Known limitations" for details.


Comparing two projects

For a generic "what changed between these two ACDs?" comparison (two saves of the same project, or two related variants), use diff_project() — it covers routines (rung/ST-line text), tags (value/description/data type), data types, modules, and AOIs, all by name/content, not by position:

from acd import load_acd, diff_project

project_a = load_acd("MyController_v1.ACD")
project_b = load_acd("MyController_v2.ACD")

diff = diff_project(project_a, project_b)
for (program_name, routine_name), routine_diff in diff.get("routines", {}).items():
    print(program_name, routine_name, "->", routine_diff["status"])
    for change in routine_diff.get("changes", []):
        print(" ", change["op"], change["old"], "->", change["new"])

for key, tag_diff in diff.get("tags", {}).items():
    print(key, "->", tag_diff)

Routine content is compared with difflib.SequenceMatcher alignment, not a naive index-by-index zip — two routines with a different rung count (very common even between two saves of "the same" logic) still diff correctly instead of raising IndexError. Data types/modules/AOIs are compared by name presence only (added/removed), not deep member/parameter layout. A tag's "value" entry is shown in full for small/scalar values, but a large container (typically a UDT array tag's decoded value) is summarized instead of dumped in full — e.g. {"summary": "list[64] vs list[64]: 3 of 64 common elements differ", "differing_indices": [3, 10, 41]} — so comparing two large, genuinely different projects doesn't produce an unreadable wall of raw array values.

If the request is specifically about I/O address wiring (not a general diff), use the narrower diff_io_addresses() instead — it reports only I/O tag address changes ("IO024:I.Data[0].13", "Remote_GraderConsole:3:I.Pt13.Data", "Local:10:I.Data.11", ...) and nothing else, so it's the wrong default for a broad comparison:

from acd import diff_io_addresses, find_io_addresses, io_addresses_by_routine

diff = diff_io_addresses(project_a, project_b)
for (program_name, routine_name), changes in diff.items():
    print(program_name, routine_name)
    print("  removed:", changes["removed"])
    print("  added:  ", changes["added"])

Already have two specific Routine objects (e.g. you found "the same" routine by name in two different projects) and just want that one routine's diff? Use diff_routine() instead of a whole-project scan — and don't manually zip/print routine_a.rungs and routine_b.rungs side by side by index to eyeball it: a single rung inserted or removed anywhere shifts every later rung's index, making an otherwise-unchanged tail look completely different in a naive side-by-side printout even though nothing there actually changed:

from acd import diff_routine

print(diff_routine(routine_a, routine_b))
# {'status': 'changed', 'changes': [{'op': 'delete',
#   'old': ['JSR(P_Landing,0);', 'JSR(Storage_Table,0)...', 'JSR(Planer_Outfeed,0);'],
#   'new': []}]}
# -- the other rungs (which shifted position by 3) are correctly recognized
# as unchanged and don't appear in "changes" at all.

find_io_addresses(text) extracts the raw list of I/O addresses from a single rung/ST-line; io_addresses_by_routine(project) gives the whole project's routine-by-routine breakdown without diffing.


Editing a project and getting the change into Studio 5000

save_acd() alone will NOT produce a file real Studio 5000 accepts if anything changed. Studio enforces a FileInfo.Dat checksum on open, seeded by a per-installation signing key this library does not have (and cannot derive from the ACD itself — see acd/integrity/ and CLAUDE.md's "ACD write-back" section). A save_acd() round-trip with zero edits reproduces the original file byte-for-byte, which is a useful sanity check, but any real edit needs a different path:

Use export_routine() to export a single routine as a partial L5X, then import it via Studio 5000's own native "Import Routine" feature (right-click a Routines folder → Import Routine…). Studio does the actual binary write and re-signing itself, so FileInfo.Dat is never a concern. This is verified end-to-end against real Studio 5000 for three edit classes: editing a rung, editing an existing tag's fields (description, value, …), and creating a brand-new tag.

Editing a rung:

from acd.api import load_acd, export_routine

project = load_acd("MyController.ACD")
routine = project.controller.programs[0].routines[0]

routine.rungs[0] = "XIC(MySensor)OTE(MyOutput);"
export_routine(project, routine, "MyRoutine.L5X")
# Then in Studio 5000: right-click the Routines folder -> Import Routine... -> MyRoutine.L5X

Editing a tag (description, value, …) works the same way, via a "carrier" routine that already references the tag — export_routine() embeds a full <Tag> definition for every tag a routine's rungs reference, and Studio's Import Routine dialog offers to overwrite a tag when the imported copy differs from the project's own:

tag = next(t for t in project.controller.tags if t.name == "MyTag")
tag._comments = [("", "New description")]  # ("", text) is the tag's own whole-tag description

# Find (or pick) any routine whose rung text already references "MyTag"
routine = project.controller.programs[0].routines[0]
export_routine(project, routine, "MyRoutine.L5X")
# Import in Studio; accept the prompt to overwrite MyTag's description.

A tag with no reference anywhere in ladder/ST logic (HMI-only or legacy tags, commonly ~30-60% of a real project) can't be carried this way — there's no routine to attach it to.

Creating a brand-new tag uses the identical mechanism — construct a new Tag, reference it from a rung (a real one, or a harmless one guarded by an always-false condition if you don't want to change actual logic), and export/import the same way. Studio decides create-vs-overwrite based on whether the tag name already exists in the project, so no special-casing is needed.

See export_routine()'s own docstring and CLAUDE.md's "Native-import escape hatches" section for the full mechanism, verified dependency-closure behavior (UDTs, AOIs, Modules, JSR-called routines), and known limitations.


Patching rung text directly into the ACD binary (limited)

patch_rungs()/save_acd() can rewrite SbRegion.Dat (rung text) in place without going through Studio at all — useful for a byte-exact round-trip check, but the output will not open in real Studio 5000 unless you've registered a valid FileInfo.Dat signing key (see "Integrity / project key" below):

from acd.api import load_acd, save_acd, patch_rungs

project = load_acd("MyController.ACD")
routine = project.controller.programs[0].routines[0]
changes = {routine._rung_ids[0]: "XIC(MySensor)OTE(MyOutput);"}

patch_rungs(project, changes)
save_acd(project, "MyController_modified.ACD")

Only SbRegion.Dat (rung text) is re-serialised. Other object types (tags, data types, AOI definitions, modules) pass through as raw bytes and are preserved verbatim — there is no binary serializer for Comps.Dat, so editing those structures in the Python object model has no write-back path via save_acd() at all (use export_routine() above instead).


Extract raw database files

Unzip all embedded files (.Dat, .XML, etc.) to a directory for inspection:

from acd.api import ExtractAcdDatabase

ExtractAcdDatabase("MyController.ACD", "output/").extract()
# output/ now contains Comps.Dat, SbRegion.Dat, Comments.Dat,
#   Nameless.Dat, QuickInfo.XML, TagInfo.XML, XRefs.Dat, ...

Extract raw database records to files

Save every individual binary record from the Comps database as its own file, useful for reverse-engineering the record format:

from acd.api import ExtractAcdDatabaseRecordsToFiles

ExtractAcdDatabaseRecordsToFiles("MyController.ACD", "output/").extract()

Dump Comps database as a navigable folder tree

Writes the entire Comps database as a directory tree where each node is a .dat file. A log file records the CIP class and instance for each record:

from acd.api import DumpCompsRecordsToFile

DumpCompsRecordsToFile("MyController.ACD", "output/").extract()
# Produces output/output.log  +  output/<comp_name>/<comp_name>.dat  (recursive)

Integrity / project key

Studio 5000's SDK validates ACD containers using a FileInfo.Dat checksum seeded by a project-specific key. The library can read and write this key, recompute the checksum, and verify that a loaded project matches the source ACD:

from acd.api import load_acd
from acd.integrity import get_fileinfo_key, set_fileinfo_key, verify_loaded_acd

project = load_acd("MyController.ACD")

# Check if a signing key is present
key = get_fileinfo_key(project)

# Register a key (32 bytes for modern Studio, 126 for older)
set_fileinfo_key(project, b"\\x00" * 32)

# Verify the loaded project matches the original ACD
ok = verify_loaded_acd(project, "MyController.ACD")

When a key is registered, save_acd() recomputes FileInfo.Dat so the SDK accepts the output. Without a registered key, the container is written as-is (byte-equal round-trip of unmodified streams).


Low-level access via ExportL5x

For direct SQLite access to the parsed ACD databases:

from acd.l5x.export_l5x import ExportL5x

export = ExportL5x("MyController.ACD")

# Raw SQLite cursor — full access to comps, rungs, region_map, comments, nameless tables
cur = export.cur
cur.execute("SELECT comp_name, object_id FROM comps WHERE parent_id=0 AND record_type=256")
row = cur.fetchone()
ctrl_name, ctrl_id = row[0], row[1]

# High-level objects
controller = export.controller
project    = export.project

export.close()   # release the SQLite connection

Working-directory default differs from load_acd(). With no temp_dir argument, ExportL5x extracts into a folder next to the source file (MyController.ACDMyController/, in the same directory) and leaves it there — handy for inspecting the raw .Dat/.Idx files or the SQLite DB afterward. load_acd() (above) instead uses a system temp directory and deletes it automatically, so a one-shot load doesn't clutter your project folder. Pass temp_dir= explicitly to either one to control this yourself.

Always call close() when you are done, especially on Windows, to release the file lock on the SQLite database.


Project structure

acd/
├── api.py                  # Public API (load_acd, save_acd, patch_rungs, ...)
├── l5x/
│   ├── export_l5x.py       # ACD -> SQLite -> Python objects
│   └── elements.py         # Dataclasses + Builder classes for all project elements
├── database/               # Binary .Dat file reader
├── record/                 # Record parsers (Comps, SbRegion, Comments, Nameless)
├── generated/              # Kaitai Struct generated parsers (comps, comments, ...)
├── integrity/              # FileInfo.Dat checksum and project key management
└── zip/                    # ACD archive extraction and writing

Running the tests

pip install -e ".[dev]"
pytest

Developing

Sections of the code are generated from kaitai template (.ksy) files in the resources/templates folder. These are generated during the install phase. The python scripts which are generated are located in the acd/generated folder.