This is both a code and documentation issue, since there are these two checks for -C in kwargs (which should not be required for meca):
# Add in plotting options, if given, otherwise add 0s
for arg in plot_longitude, plot_latitude:
if arg is None:
spec.append(0)
else:
if "C" not in kwargs:
kwargs["C"] = True
spec.append(arg)
Activity
seisman commentedon Mar 21, 2021
GMT made some changes to the -C option recently (GenericMappingTools/gmt#4873), although it's still backward-compatible.
We should upgrade the
Figure.meca()syntax to match the GMT 6.2.0 syntax.maxrjones commentedon Mar 21, 2021
Thanks for pointing this out - lesson learned to check the 'latest' documentation in addition to the 'dev' documentation before posting.