FAQ and troubleshooting

Answers to the questions that come up most often. For the JSON rule format see RULE_AUTHORING.md, for complete rules see EXAMPLES.md, and for internals see ARCHITECTURE.md.

Installation and updates

Which build should I use: Setup or portable?

  • Setup (Synector-Setup-<version>-Windows-x64.exe) installs into Program Files, adds a Start Menu shortcut, registers App Paths and an uninstaller. Updates are applied by downloading and running the new setup silently.
  • Portable (Synector-v<version>-Windows-x64.zip) is a single Synector.exe. Extract it anywhere and run it; updates replace the executable in place.

Both forms share the same configuration in %LOCALAPPDATA%\Synector\ and the same daemon.

Windows SmartScreen or antivirus warns about the download

Synector is distributed through GitHub Releases. Verify the file before running it:

Get-FileHash .\Synector-Setup-<version>-Windows-x64.exe -Algorithm SHA256

Compare the result with the matching line in SHA256SUMS.txt from the same release. If the hashes match and you downloaded from the official release page, the warning is a reputation prompt rather than a sign of tampering. Do not disable antivirus protection or add exclusions for files whose hash you have not verified.

Do I need to run as administrator?

Synector starts elevated by default; --no-elevate opts out. Elevation enables:

  • kernel ETW process tracing (otherwise Synector falls back to adaptive Toolhelp32 polling);
  • input simulation into elevated applications through UIPI;
  • memory/priority/affinity tuning of elevated processes;
  • silent highest-privilege logon autostart through Task Scheduler.

Without elevation most rules still work, but a rule that targets an elevated game or application, or that relies on ETW, may not fire.

Does Synector start with Windows?

The daemon registers a Task Scheduler autostart entry on first launch. It can be disabled in Settings. The entry is separate from the installer: uninstalling removes it, and running portable without autostart leaves the machine untouched.

How do updates work?

The daemon checks GitHub Releases, selects the right asset, downloads it and verifies the SHA-256 digest published by the GitHub API. An installed copy downloads the release's setup and starts it silently; a portable copy replaces its own executable. Progress is shown in the tray and overlay notifications. Auto-install is optional and can be turned off in Settings.

If an update fails, check the log in %LOCALAPPDATA%\Synector\logs\, make sure the app is not running from a read-only or protected folder, and install the latest release manually. The configuration directory is preserved either way.

Can I downgrade?

Install the older release over the current one. Configuration is versioned per section, but downgrades are not a supported migration path: keep an export of your rules (--rules-export rules.json) or a SYN1: share code before changing versions, and restore from it if the older build cannot read the current data.

Upgrading from 2.8 or older

The 2.9 storage format is split into independent section files and older configuration is not migrated automatically. Export the rules from the old version (--rules-export or a share code) and import them into the new one. Old PH1: share codes are not accepted by 2.9 and later; re-export them from the updated app.

Daemon and GUI

Does closing the window stop my rules?

No. The daemon is the tier that owns rules and triggers; the GUI is only a client. Closing the GUI, or never opening it, leaves automation running. Use the tray menu to pause, open the window or exit the daemon.

Where are configuration and logs?

  • Configuration: %LOCALAPPDATA%\Synector\ (settings.json, rules.json, library.json, runtime.json). Set SYNECTOR_CONFIG_DIR to relocate the whole directory.
  • Logs: %LOCALAPPDATA%\Synector\logs\, one file per day, 7-day retention and an 8 MiB cap per file.

The log level comes from SYNECTOR_LOG (off, error, warn, info, debug, trace; default info). Restart Synector after changing it.

How do I back up or move my setup?

Stop Synector first, then copy the whole %LOCALAPPDATA%\Synector\ directory. For rules alone, Synector.exe --rules-export rules.json or a SYN1: share code is enough. While the daemon is running it is the only writer; editing the files underneath it is not supported.

A configuration file is corrupt or I want a clean start

A section that fails to parse is renamed to <name>.corrupt-<timestamp> before defaults replace it, so the original is not destroyed. To start clean, stop Synector and remove or rename the section files; to recover, restore a backup over them while the daemon is stopped.

Why are there two Synector processes?

The tray daemon and the GUI are separate tiers of the same executable. Overlay windows are additional borderless processes supervised by the daemon. Seeing several Synector processes is normal when overlays are open. Each tier has a single-instance mutex, so a second daemon or GUI does not start.

Rules and triggers

My rule does not fire

Check, in order:

  1. The rule is enabled and has not hit a lifetime quota.
  2. The trigger target actually matches (process name, window, folder, hotkey, webhook path).
  3. Preconditions are satisfied. A false condition prevents the pipeline from starting.
  4. cooldown_seconds or a periodic quota is not skipping the run. --rules-list shows the counter and period.
  5. The rule is not stuck in an active execution, and stop_on_error did not halt it after a failed step.
  6. The daemon logs in %LOCALAPPDATA%\Synector\logs\ do not show a permission or target-not-found error.

Process detection uses ETW when elevated and adaptive Toolhelp32 polling otherwise; both feed the same trigger surface, so a missing ETW session alone does not disable process rules.

What is the difference between a cooldown and a quota?

  • Cooldown is a minimum delay between two triggered runs.
  • Lifetime quota (max_executions without quota_period) pauses the rule after the limit. --rules-reset clears the counter and re-enables it.
  • Periodic quota (quota_period) keeps the rule enabled and skips executions until the period rolls over.

See RULE_AUTHORING.md#quotas for reset semantics and JSON fields.

Why is my infinite macro rejected?

An infinite macro has no natural end. The CLI validator only accepts it with a global-hotkey trigger, because every other trigger offers no manual cancellation path. The Rule Builder warns and dims the steps after the infinite action.

How do I trigger Synector from another program?

Use a webhook trigger and send a request to http://127.0.0.1:48123/api/v1/trigger/<endpoint_path> (a rule id also works). The server is local-only. See RULE_AUTHORING.md for the JSON format and EXAMPLES.md for a complete rule.

Why does a hotkey not respond?

Global hotkeys are detected by polling GetAsyncKeyState, not by RegisterHotKey, which is what allows mouse-button combinations and hold/repeat modes. A combination already consumed by another application or by Windows may still not reach Synector. Try a different combination and check the logs. Hold mode repeats the pipeline while the key is held; repeat-while-held without hold mode loops until the hotkey is pressed again.

Are share codes safe?

SYN1: codes carry a checksum and are decoded with bounds on code length, decompressed size and rule count. Imported rules are created disabled by default; review them before enabling. A share code can contain scripts, webhook actions and other powerful steps, so only import codes from people you trust. See ARCHITECTURE.md#sharing-and-backup.

PowerShell does not show CLI output

Release builds use the Windows GUI subsystem, so PowerShell does not wait for them and cannot capture their output or exit code. Prefix commands with cmd /c:

cmd /c "Synector.exe --rules-validate rule.json"
cmd /c "type rule.json | Synector.exe --rules-apply -"

Tools that spawn the process with piped stdio and wait for it, such as Python subprocess.run or Node child_process, work directly.

Troubleshooting

The daemon does not start or exits immediately

Another Synector instance may hold the single-instance mutex; check Task Manager for an existing daemon or GUI. Look for an update-file cleanup failure or a permission error in the log. Starting from a folder that requires higher privileges than the process has can also prevent self-update or overlay processes from starting.

An overlay is not visible

Open the Overlay Studio and start calibration: the overlay becomes draggable and can be moved to the intended monitor. Check multi-monitor placement and DPI scaling in the overlay definition. The daemon must be running for overlays to exist. WDA_EXCLUDEFROMCAPTURE keeps an overlay out of screen capture; it does not hide it on screen.

A macro does not register in a game

Synector replays hardware scan codes and holds presses for at least 30–35 ms, which covers most DirectInput games, but some titles and anti-cheat systems ignore or flag synthetic input. Run Synector elevated if the game is elevated (UIPI otherwise blocks input). Relative camera turns use Raw Input-compatible deltas and should be recorded in the same coordinate mode the game expects. Use automation only where the application permits it.

Audio actions fail

Check that the requested default device exists and is enabled, and that the target process is playing audio. Per-application volume and channel balance depend on the Windows audio session for that process; a stopped or suspended app may not expose one. Audio format changes can temporarily interrupt playback by design.

High CPU or constant disk writes

Polling is adaptive and backs off when no rule uses a trigger, but many independent polling triggers, a fast interval schedule or trace logging increase load. Process triggers use ETW when elevated; without elevation they fall back to snapshot polling. Runtime counters and overlay positions are written coalesced, not on every event.

The webhook port is busy

The local webhook server binds 127.0.0.1:48123, and the port is fixed. If another application already owns it, the server cannot start and webhook-triggered rules will not fire; the daemon log records the bind error. Close the conflicting application.

Where do I report a bug or a security issue?

  • Bugs and feature requests: GitHub Issues. Include the Synector version, winver, whether the app was elevated, reproduction steps and the relevant log lines with secrets removed.
  • Security problems: follow SECURITY.md and report privately. Do not open a public issue.