| 1 | +""" |
| 2 | +According to Faraday's law, the emergence of electric currents depends on the change in |
| 3 | +magnetic flux. Therefore, we write that the time variation of the magnetic flux is |
| 4 | +equivalent to an electric potential measured in volts (V), which, for historical |
| 5 | +reasons, is called the induced electromotive force (ε). This relationship is expressed |
| 6 | +by the following formula: |
| 7 | +
|
| 8 | +--------------- |
| 9 | +| ε = ΔΦ / Δt | |
| 10 | +--------------- |
| 11 | +
|
| 12 | +ε --> induced electromotive force (V - volts) |
| 13 | +
|
| 14 | +ΔΦ = ΦF - Φi - variation in magnetic flux (Wb) |
| 15 | +
|
| 16 | +Δt - time interval (s) |
| 17 | +
|
| 18 | +Furthermore, due to the principle of conservation of energy, we need to add a negative |
| 19 | +sign to Faraday's law. This signal was introduced by Lenz's Law, which allows us to |
| 20 | +determine the direction of the electric current: |
| 21 | +
|
| 22 | +An electric current will always be formed in a direction such that the magnetic flux it |
| 23 | +produces opposes the magnetic flux that induced it. |
| 24 | +
|
| 25 | +The combination of these pieces of information gives rise to the Faraday-Lenz Law. |
| 26 | +Check it out: |
| 27 | +
|
| 28 | +----------------- |
| 29 | +| ε = - ΔΦ / Δt | |
| 30 | +----------------- |
| 31 | +
|
| 32 | +(Description adapted from https://en.wikipedia.org/wiki/Faraday%27s_law_of_induction ) |
| 33 | +""" |
| 34 | + |
| 35 | + |
| 36 | + |
| 37 | +def check_args(final_flux: float, initinal_flux: float, time_interval: float) -> None: |
| 38 | + """ |
| 39 | + Check that the arguments are valid |
| 40 | + """ |
| 41 | + |
| 42 | + # Ensure valid instance |
| 43 | + if not isinstance(final_flux, (int, float)): |
| 44 | + raise TypeError("Invalid final flux. Should be an integer or float.") |
| 45 | + |
| 46 | + if not isinstance(initinal_flux, (int, float)): |
| 47 | + raise TypeError("Invalid final flux. Should be an integer or float.") |
| 48 | + |
| 49 | + if not isinstance(time_interval, (int, float)): |
| 50 | + raise TypeError("Invalid time interval. Should be an integer or float.") |
| 51 | + |
| 52 | + # Ensure valid time interval |
| 53 | + if time_interval < 0: |
| 54 | + raise ValueError("Invalid time interval. Should be a positive number.") |
| 55 | + |
| 56 | + |
| 57 | +def induced_electromotive_force( |
| 58 | + final_flux: float, |
| 59 | + initinal_flux: float, |
| 60 | + time_interval: float |
| 61 | +) -> float: |
| 62 | + """ |
| 63 | + >>> induced_electromotive_force(50.0, 20, 3.0) |
| 64 | + -10.0 |
| 65 | + >>> induced_electromotive_force(40, 30, 10.0) |
| 66 | + -1.0 |
| 67 | + >>> induced_electromotive_force(30.0, 50.0, 10) |
| 68 | + 2.0 |
| 69 | + >>> induced_electromotive_force(100, 100.0, 20.0) |
| 70 | + 0.0 |
| 71 | + >>> induced_electromotive_force(10.0, 2.0, -2.0) |
| 72 | + Traceback (most recent call last): |
| 73 | + ... |
| 74 | + Invalid time interval. Should be a positive number. |
| 75 | + >>> induced_electromotive_force(11.0, 'a', 5.0) |
| 76 | + Traceback (most recent call last): |
| 77 | + ... |
| 78 | + TypeError: Invalid final flux. Should be an integer or float. |
| 79 | + """ |
| 80 | + check_args(final_flux, initinal_flux, time_interval) |
| 81 | + flux_variation = final_flux - initinal_flux |
| 82 | + return round(-flux_variation / time_interval, 1) |
| 83 | + |
| 84 | + |
| 85 | +if __name__ == "__main__": |
| 86 | + from doctest import testmod |
| 87 | + |
| 88 | + testmod() |
0 commit comments