A model of an optical system is only as good as what it knows. The design says the compressor matches the stretcher; the lab says the pulse has 800 fs² left over, the amplifier narrowed the spectrum and an etalon added a post-pulse. The fitting plugin closes that gap in four steps:
- Transform elements (
"type": "transform") are physical changes to the beam that you insert where they happen: spectral phase (dispersion), spectral amplitude (gain narrowing, filters), energy, polarisation errors, contrast degradation (replicas, phase noise, ASE pedestals) and wavefront errors. Each is a physical operator on the complex field, so spectrum, pulse, contrast and beam stay consistent with each other. - Measured data (
"measured"on any instrument, a core feature) compares a simulated instrument with your recording: CSV, NPZ or JSON, curves, 2-D traces and scalar readings, at the recording instrument's resolution and sampling. - Fitting (
"fit"in the run spec) finds the transform numbers you marked, and any other number in your files, from all recordings at once. It reports them with uncertainties in three layers (simulated → inferred → believed) and with an influence map, and it writesfitted-system.ufs. That file is your system with the fitted transforms in place, ready to run on new inputs with higher fidelity than the design alone. - Backward propagation (
"backward"in the run spec) runs the system in reverse. Give it the field measured at the output and it finds the field at every plane upstream, up to the input.
How this relates to the core: a measured input spectrum ("pulse": {"shape": "spectrum", ...}, see the
run spec) is a core feature. It replaces the input shape and propagates forward
only. Transforms are the opposite tool. They describe what the system does to any pulse, so they are fitted once
and then reused with other inputs, and they can be undone for backward propagation.
Worked example: docs/examples/DigitalTwin/transforms fits a CPA line's residual
dispersion, gain narrowing, post-pulse and ASE pedestal from a spectrum, a d-scan, a cross-correlator and a power
meter. It then applies the fitted line to a new seed and propagates the measured output back to the seed. Example 21
(Diagnostics/measured-data) and Tutorial 4
fit numbers of an existing system by path.
// run spec: recordings on the instruments, and a fit block (no parameter list needed)
"fit": {},
"instruments": [
{ "kind": "spectrometer", "resolutionM": 0.2e-9, "measured": { "file": "data/spectrum.csv", "background": "auto" } },
{ "kind": "dscan", "gddRangeS2": [-2e-26, 2e-26], "measured": "data/dscan.npz" },
{ "kind": "crossCorrelator", "rangeS": [-15e-12, 15e-12], "measured": { "file": "data/xc.csv", "scale": "log" } }
]ultrafast run line.ufs run-fit.json -o results-fit # fit.json, fitted-system.ufs, plots with ultrafast-plot
ultrafast run results-fit/fitted-system.ufs new-seed.json -o new # the fitted line on a new input{ "id": "ID", "type": "transform", "operators": [ { "kind": "...", ... }, ... ], "regularization": 1e-3 }The operators are applied in order. Put the element where the change happens: after the stretcher for its residual dispersion, after the amplifier for gain narrowing, at the end for an etalon in front of the diagnostics. Several transform elements in one system are fine; each one's numbers are fitted together.
A transform describes a physical object (a mirror's figure error, a window's damage, a filter). When the light meets that object several times, for example the passes of a multipass cell that is built element by element, write the transform once and add the later passes as copies:
{ "id": "mirror", "type": "transform", "operators": [ { "kind": "wavefront", "zernike": { "4": { "value": 0.05, "fit": true } } } ] },
{ "id": "mirror2", "sameAs": "mirror" }The fit parameters exist once, on mirror; mirror2 always has the fitted values. What differs from pass to pass is not part of
the transform: each copy receives its own pulse, spectrum, energy and beam, and has its own record and loss booking. Backward
propagation undoes each copy on its own pass. Details: identical elements.
| kind | what it is | parameters (all may be fit objects) |
|---|---|---|
spectralPhase |
dispersion: φ(ω) = GDD Δ²/2 + TOD Δ³/6 + FOD Δ⁴/24 + 5th Δ⁵/120 about the centre wavelength, plus optional spline knots | gddFs2, todFs3, fodFs4, fifthFs5 (or gddS2, todS3, fodS4); centerWavelengthM / Nm (default: the element's carrier); knots: {wavelengthsM or wavelengthsNm, phaseRad} |
spectralAmplitude |
power transmission T(λ): gain narrowing, filters, spectral clipping | shape: gaussian / superGaussian (fwhmM / fwhmNm, centerWavelengthM / Nm, order), tilt (tiltDbPerNm, curvatureDbPerNm2), spline (knots: wavelengths with transmission or transmissionDb), model (any filter model); peak; passive (default true: T ≤ 1); causal (adds the minimum phase, see below) |
energy |
a flat power transmission | transmission or gainDb |
delay |
a pure group delay (matters only relative to other beams) | delayS or delayFs |
jones |
polarisation errors: retarder → diattenuator → rotation | retardanceRad, axisDeg, diattenuation (power lost by the weak axis, 0…1), diattenuationAxisDeg, rotationDeg |
replica |
a coherent pre- (negative delay) or post-pulse from a double reflection or an etalon: H = 1 + √r e^{i(Δτ + φ + GDD Δ²/2)} | delayS / delayFs / delayPs; relativeIntensity or relativeIntensityDb; phaseRad; gddFs2 |
phaseNoise |
correlated spectral phase and amplitude noise: the coherent pedestal of stretchers and shapers | rmsRad, amplitudeRms, correlationNm / correlationRadPerS, seed |
pedestal |
an incoherent background that no linear filter makes: an ASE plateau or exponential wings | type: ase (relativeIntensity / relativeIntensityDb or energyFraction, durationS) or exponential (level / levelDb, riseS, fallS); bandwidthFwhmNm; seed |
nonlinearPhase |
a Kerr-like nonlinear phase of the temporal intensity, φ(t) = bRad · I(t) / max I (the B-integral of a thin plate; exactly invertible; it changes the spectrum, not the temporal intensity) |
bRad |
wavefront |
wavefront error: Zernike terms (Noll index → waves rms) and pointing | zernike: {"4": 0.1, "11": 0.02}; radiusM (default: the beam's 1/e² radius); wavelengthM (default: the carrier); tiltXRad, tiltYRad |
The parameter reference with types and defaults is generated in the option reference
(fitting:operator).
Linear and field operators. All operators except pedestal, nonlinearPhase and wavefront are linear: a 2×2 Jones transfer
H(ω). Consecutive linear operators compile into one ordinary linear term of the engine. The grid planner therefore
sees their dispersion and replica delays, they appear in the loss budget (mechanism transform), and backward
propagation inverts them exactly. pedestal adds light and wavefront acts on the transverse profile, so they run on
the whole field. Linear operators placed between field operators run inside that step, where the grid planner
cannot see their dispersion; put large GDD before or after the field operators.
Causality (Kramers–Kronig). A physical filter cannot change the amplitude without changing the phase. With
"causal": true, spectralAmplitude adds the minimum phase belonging to its amplitude, from the folded cepstrum
(the Bode gain–phase relation). Its impulse response is then causal, and the delay a real band-pass filter imposes
on the edges of the spectrum is part of the model. The relation is evaluated over the simulation band.
Wavefront. On a 1-D beam (the default temporal model) a wavefront error does not change the pulse. The element
reports wavefrontRmsWaves and a Strehl estimate exp(−(2π σ)²), with a note. When the beam carries a transverse
profile (spatial models), the optical path difference is applied to it at every
frequency. Downstream spatial elements, cameras, wavefront sensors and far-field samplings then see it. Radial models
apply only the rotationally symmetric terms (defocus, spherical aberration).
Your own operators. Derive from TransformOperator (C#), implement Transfer (linear) or Apply and Invert
(field operators), and register a factory with TransformOperators.Register("myKind", spec => new MyOperator()) from
your plugin's Register. Read its numbers with FitValues.Num(Spec, "key", default) so they can be fit objects. Put
its keys under "params", which is free-form in the schema; fit objects there are found like any other. Learned or
measured transfer matrices fit here.
Any number of an operator can be written as a fit object in place of the number:
"gddFs2": { "value": 0, "fit": true, "min": -3000, "max": 3000, "prior": 500, "scale": 200, "unit": "fs^2" }| key | meaning |
|---|---|
value |
the number: used by plain runs, and the start of a fit |
fit |
true to fit it (default false: the object is then just a number with metadata) |
min, max |
bounds (recommended: they also set the scale) |
prior |
Gaussian prior: a σ (mean = value) or {"mean": ..., "sigma": ...} |
scale, step |
typical change (default (max − min)/4, else a per-quantity default such as 500 fs² for GDD), finite-difference step (1e-3 × scale) |
name, unit |
labels for reports (default ID.kind.key, unit from the key suffix) |
Alternatively, list names in the operator. This form is convenient for arrays such as spline knots:
{ "kind": "spectralPhase", "knots": { "wavelengthsNm": [720, 750, 775, 800, 825, 855, 890], "phaseRad": [2, 1, 0.3, 0, 0.3, 1, 2] },
"fit": ["knots.phaseRad"], "bounds": { "knots.phaseRad": [-10, 10] }, "smoothness": 0.01 }fit names keys (dotted for nested ones). An array fits every element, each with the given bounds and priors.
smoothness adds a penalty on the second differences of fitted knots (their curvature), which keeps a spline phase
or transmission from oscillating between data points. The splines use not-a-knot ends, so a pure GDD or TOD phase is
reproduced exactly by the knots.
A plain run (no "fit" block) uses the value of every fit object. It notes how many parameters are marked, so the
same system file serves for fitting and for prediction.
"fit": {
"estimator": "levenbergMarquardt", // or "cmaes", "mcmc", or one a plugin registers
"parameters": [ // optional: numbers by path, in addition to the marked ones
{ "path": "instrument:spec/resolutionM", "initial": 1e-9, "min": 1e-10, "max": 5e-9 },
{ "path": "pulse/energyJ", "min": 1e-4, "max": 2e-3, "prior": { "mean": 1e-3, "sigma": 5e-5 } }
],
"maxIterations": 30, "freezeGrid": true, "parallel": 1
}What is fitted. Every number marked in a transform element is fitted, plus every entry of parameters. Paths
address any number in the files:
| path | where |
|---|---|
pulse/energyJ, pulse/chirp/gddFs2, pulse/centerWavelengthM |
the run's pulse |
element:ID/lengthM, element:amp/pump/powerW, element:ID/operators/0/gddFs2 |
a property of an element (nested objects and lists with /, list indices from 0) |
instrument:NAME/resolutionM, instrument:NAME/detector/calibration |
an instrument of the run (by name, else by kind): instrument-response parameters such as resolution or calibration are fitted like the physics |
material:FusedSilica/n2 |
a material property, applied as an override |
run/physics/..., system/... |
anything else in the run or system file |
Path entries take name, initial (default: the value in the files), min, max, scale, step, unit,
prior.
| estimator | what it does | runs | use when |
|---|---|---|---|
levenbergMarquardt (default) |
local, gradient-based least squares on scaled variables with bounds; forward-difference Jacobians | ~ (n + 1) × iterations | you start reasonably close; most fits |
cmaes |
covariance-matrix adaptation evolution strategy: global, derivative-free; finishes with Levenberg–Marquardt (polish) |
population × generations (4 + 3 ln n per generation, maxIterations 60) |
several minima, a poor start, noisy costs; give min/max for every parameter |
mcmc |
affine-invariant ensemble sampler (emcee stretch move) of the posterior exp(−χ²/2), started from a Levenberg–Marquardt optimum | walkers × steps (default max(2n+2, 8) × 200) | you need credible intervals and non-Gaussian uncertainties |
Options are in the fit block. All estimators take maxIterations, tolerance and seed. CMA-ES also takes
population, sigma0 (initial step in units of each parameter's scale), polish and polishIterations. MCMC also
takes walkers, steps, burnIn (fraction, 0.5), thin, start (optimum | initial) and spread.
parallel: k runs k simulations at a time: Jacobian columns, CMA-ES populations, MCMC half-ensembles. Each
simulation already uses all cores for its FFTs, so this helps most for small grids.
Your own estimator. Implement IEstimator (Name, Description, Estimate(FitProblem, options)) and call
Estimators.Register(new MyEstimator()) from a plugin. The problem gives the residual function (one simulation
per call), bounds, scales and steps. Return the best point, plus posterior samples if you have them. Ensemble
Kalman, Bayesian-optimisation and learned estimators plug in this way.
- Weighted least squares. The fit minimises χ² = Σ ((simulated − measured)/σ)² over every point of every
measured instrument, plus the priors ((x − mean)/σ)² and the smoothness penalties. Data compared in dB
(
"scale": "log") contribute (Δ dB / σ_dB)². - Frozen grid. The time–frequency grid is fixed for all runs (
freezeGrid, default on) at twice the planned bandwidth, so the grid does not jump between nearby parameter values. Set it to false when you give a fixed grid yourself ("grid": {"auto": false, ...}). That keeps random operators (ASE pedestals, phase noise) on exactly the same realisation as your forward runs. - Uncertainties. These come from the covariance C = (JᵀJ)⁻¹ at the optimum, computed by a pseudo-inverse so
that directions the data cannot resolve do not explode. If the reduced χ² is above 1, they are scaled up by
√(reduced χ²). With
mcmcthey come from the posterior samples instead. - Diagnostics (in
warnings):- correlations above 0.95;
- parameters that affect no instrument, or that only their prior determines;
- unidentifiable combinations (null directions of JᵀJ);
- parameters at a bound;
- no convergence;
- a low MCMC acceptance rate.
fit.json → layers keeps the three states of knowledge apart:
| layer | what it is |
|---|---|
simulated |
the system as described, at the initial values: χ² per instrument and every instrument reading. This is what the design predicts. |
inferred |
the best fit: the same readings with the fitted values (the run result itself). This is what the data say the system is. |
believed |
the fitted values with their uncertainty: σ, 68 % and 95 % intervals (Gaussian from the covariance, or credible intervals and medians from MCMC samples), and the predictions with 1σ for every instrument and element |
The measurement figure draws the simulated layer as a dashed curve ("before the fit") next to the fitted one and its 1σ band.
fit.json → influence gives, for each parameter, the share of its Fisher information that each instrument
provides (Σ J² over that instrument's points divided by the total), with priors as its own entry. It shows which
measurement determines which number: in example 26 the d-scan fixes the GDD (99 %), the cross-correlator fixes the
post-pulse and pedestal levels (98–100 %), and the FOD is half data, half prior. A parameter that is 100 % priors
is not measured at all. fit.png draws the map.
The best run is the run result: all instruments, elements, probes and plots are at the fitted values. In addition, each number gets a 1σ uncertainty by linear propagation, σ² = gᵀ C g:
- every scalar of every instrument, measured or not (
<value>Sigmanext to the value, andpredictions["<instrument>.<value>"]); - per element:
energyOutJ,fwhmS,peakPowerW,spectralFwhmM,bIntegralRad; - a 1σ band on each compared curve or trace (
<name>_simulated_sigma).
To predict an instrument you do not have, add it to the run without "measured".
| file / key | contents |
|---|---|
fit.json (and summary.json → fit) |
estimator, converged, iterations, evaluations, points, chi2Initial, chi2Final, dataChi2Final, reducedChi2, parameters (name, path, origin, unit, initial, value, sigma, bounds, atBound, prior), correlation, costHistory, instruments (χ² and rms error before / after), predictions, layers, influence, provenance, warnings, notes |
fitted-system.ufs |
your system file with the fitted values in place of the fit objects and the operators' fit lists removed: a plain system for new inputs. source.fitted records the fitted values with σ and points to fit.json. |
fitted-run.json |
the run spec with fitted run-side values (pulse, instrument responses, material overrides) and the grid used |
provenance (in fit.json) |
engine and plugin versions, estimator and options, start time and duration, each data file with its SHA-256, and the origin of every parameter (marked in a transform, or listed by path) |
| arrays | <name>_nominal_on_measured (simulated layer), <name>_simulated_on_measured, <name>_simulated_sigma |
The CLI prints the parameters with σ and each instrument before → after. ultrafast-plot draws measurements.png
and fit.png.
ultrafast run results-fit/fitted-system.ufs new-input.json -o results-newThe fitted system is an ordinary system file. Change the seed, the energy or the downstream elements, and the transforms carry what the data taught the model. In example 26 the design predicts 114 fs and 730 µJ for a new 70 fs seed, while the fitted line predicts 150 fs and 460 µJ, with the post-pulse and pedestal included.
A calibration against one recording fits one operating point. A lab runs at many: pulse energies, angles, temperatures,
pressures. fit.conditions fits one set of shared parameters to all of them at once, lets chosen numbers follow
the condition (a nonlinear phase that grows with the energy), and keeps some conditions out of the fit to test
what the model predicts.
"fit": {
"conditions": [
{"name": "E0.4", "variables": {"energyJ": 4e-7}, "set": {"pulse/energyJ": 4e-7, "instrument:spec/measured/file": "e0.4.csv"}},
{"name": "E1.2", "variables": {"energyJ": 1.2e-6}, "set": {"pulse/energyJ": 1.2e-6, "instrument:spec/measured/file": "e1.2.csv"}},
{"name": "E1.4", "heldOut": true, "variables": {"energyJ": 1.4e-6}, "set": {"pulse/energyJ": 1.4e-6, "instrument:spec/measured/file": "e1.4.csv"}}
],
"parameters": [
{"path": "element:kerr/operators/0/bRad", "name": "kerr.bRad",
"dependence": {"kind": "proportional", "variable": "energyJ", "reference": 1e-6, "coefficients": [{"initial": 2.0, "min": 0, "max": 10}]}}
]
}| key | meaning |
|---|---|
conditions[].name |
label, unique. Reports use condition/instrument (for example E1.4/spec). |
conditions[].set |
path → value written into the files for this condition: a number, or a string such as a data file. Same path language as fit.parameters[].path. A path that is also a shared fit parameter is an error. |
conditions[].variables |
named numbers describing the condition. The inputs of dependence. |
conditions[].heldOut |
not in the cost. The condition is simulated at the start, at the optimum and at the Jacobian points; its chi², its curves and its prediction band come from the same covariance as the others. |
conditions[].weight |
multiplies the condition's chi² (default 1). |
parameters[].perCondition |
one value per training condition (name[condition]) instead of one shared value. |
parameters[].dependence |
the value follows a condition variable: its coefficients are the fitted parameters. |
Each condition is simulated with its own frozen grid (twice its planned bandwidth). With no conditions the fit is
unchanged: one implicit condition, instrument names without a prefix.
Held-out conditions. After the fit the report lists, per condition, the points, chi² and chi² per point
(conditions in fit.json) and warns when a held-out condition's chi² per point is more than twice
max(1, the training value): the model fits what it was given and does not predict what it was not.
u = variable / reference (reference: the mean of the training values). ξ = 2(variable − lo)/(hi − lo) − 1 on the
training range, or range. A held-out condition outside the range is an extrapolation.
kind |
value | coefficients |
|---|---|---|
constant |
c₀ | 1 |
proportional |
c₀ u | 1 (a phase proportional to the energy: the slope) |
linear |
c₀ + c₁ u | 2 |
polynomial |
Σ cₖ uᵏ | degree + 1 |
power |
c₀ u^c₁ | 2 (the exponent starts at 1) |
chebyshev |
Σ cₖ Tₖ(ξ) | degree + 1 |
network |
a small tanh network of ξ with built-in constraints (below) | 2 H + paths (H + 1) |
Each coefficient takes initial, min, max, scale, prior, step like any fit parameter
(dependence.coefficients[k]), so physical priors apply: a slope that must be positive gets min: 0. The number of
distinct training values of the variable must be at least the number of coefficients.
fit.surfaces[] fits several numbers at once as functions of one variable: the knots of a spectral phase or
amplitude over (wavelength, condition). With pathTemplate (element:t/operators/0/knots/transmission/{i}) and count
(or paths), kind: "chebyshev" and degree, every knot gets a Chebyshev series of the variable: a tensor-product
surface. Two penalties keep noise out of it: smoothnessPaths (second differences across the knots, per order) and
smoothnessVariable (second differences of the surface sampled across the variable). The existing constraints of
spline knots (passive, causal) still apply to the knot values.
A spectrometer reading is normalised, so it cannot fix the overall scale of a transmission surface; compare shapes (a knot relative to a reference knot).
kind: "network" is a physics-constrained network transform, not a physics-informed network: a small network
(hidden tanh units, default 4) from the scaled variable to one output per path, trained by the same estimators as
every other parameter (so it stays small: about 20 weights). The constraints are exact by construction, for any weights:
output: "bounded"withoutputRange: [lo, hi]:lo + (hi − lo) sigmoid(raw), always strictly inside the range (a passive transmission:[0, 1]);output: "positive": softplus;monotone: "increasing"or"decreasing": the input weights and the output weights are squared, so the output cannot decrease (increase) with the variable, also outside the training range.
weightDecay (default 1e-4) is an L2 penalty on the weights. A network has more freedom than a parametric form: use
it when the dependence has no physical form, and compare it with a polynomial on the held-out conditions.
fitted-conditions.json lists, per condition, the variables, the set edits, the frozen grid and the fitted value of every
dependent path; dependences[] stores each dependence in a form that can be evaluated at any variable value
(ultrafast_twin.DependenceModel does it in Python). fitted-system.ufs holds the shared parameters; per-condition and
dependent numbers are applied from fitted-conditions.json.
Every cost evaluation is a full simulation, and the Jacobian costs one simulation per parameter and condition: there are no analytic gradients through the engine's elements. A network with 20 weights therefore costs about 20 runs per Jacobian column set; the estimators are the existing ones (Levenberg–Marquardt, CMA-ES, MCMC). Whether linear elements could supply analytic derivatives is open; nothing here depends on it.
"pulse": { "shape": "spectrum", "energyJ": 2.6e-4, "spectrum": { "csv": "data/output_field.csv" } }, // measured at the output
"backward": { "from": "end", "to": "input", "regularization": 1e-3, "active": "error" }The run's pulse is the field measured at plane from (an element id, after that element, or "end"), typically a
spectrum with the phase from a FROG or d-scan retrieval. The engine undoes the elements between from and to in
reverse order and records the field at every plane in between. Instruments placed at those planes measure it
("at": "input" is the reconstructed input), and the reconstructed field is written to reconstructed-pulse.json
as a pulse object you can paste into a new run spec.
| element | how it is undone |
|---|---|
| linear terms (dispersion, materials, gratings, coatings, filters, polarisation optics, transform linear operators) | regularised inverse of the Jones transfer: H⁻¹ ≈ (HᴴH + ε²)⁻¹Hᴴ with ε = regularization × the largest transfer. Bins where the transmission is below ~ε are not recoverable; the record reports the fraction of the spectral energy there |
| nonlinear segments (Kerr, Raman, self-steepening in plates, gases, fibres) | integrated with z reversed, dA/ds = −L A − N(A, L − s), exact up to the step tolerance (absorption becomes gain and is capped at 1/1000 per element) |
| transform field operators | wavefront is undone exactly; an incoherent pedestal cannot be removed and is passed through with a note |
| active elements (amplifiers, crystals, spatial elements, user elements) | active: "error" (default) refuses; "linearized" undoes each as the filter A_out/A_in it was in a forward reference run of referencePulse; "identity" passes them through |
A transform element can set its own regularization. Backward propagation is deterministic and cheap: one pass,
the same cost as a forward run. It amplifies noise wherever the system attenuated the light. Give the measured
field over its full bandwidth, and prefer a larger regularization for noisy data.
The "measured" key of instruments -- recorded CSV / NPZ / JSON data compared with the simulated reading on the
recording's axis, range and resolution -- is part of the core engine and documented in
Measured data. The fit uses those comparisons: its χ² is the sum of the
instruments' χ², each weighted by the instrument's weight.
import ultrafast as uf
from ultrafast import build as b
fx = uf.plugins.module("fitting") # or: import ultrafast_fitting as fx
line = b.system("cpa", [
b.dispersion("stretcher", gdd_s2=1e-25),
fx.transform("lab", [fx.spectral_phase(gdd_fs2=fx.fit_value(0, -3000, 3000)),
fx.spectral_amplitude("gaussian", fwhm_m=fx.fit_value(20e-9, 5e-9, 60e-9)),
fx.replica(6e-12, relative_intensity_db=fx.fit_value(-50, -90, -20))]),
b.dispersion("compressor", gdd_s2=-1e-25)])
spec = b.run_spec(b.pulse(1030e-9, 100e-15, energy=1e-3),
instruments=[b.instrument("spectrometer", resolutionM=0.2e-9, measured=b.measured("spectrum.csv", background="auto")),
b.instrument("crossCorrelator", rangeS=[-15e-12, 15e-12], measured=b.measured("xc.csv", scale="log"))],
fit=fx.fit(estimator="levenbergMarquardt"))
res = uf.run(line, spec)
report = fx.fit_report(res) # fit.json as a dict: parameters, layers, influence, provenance
fitted = fx.fitted_system(res) # the system with the fitted values
new = uf.run(fitted, b.run_spec(b.pulse(1028e-9, 70e-15, energy=2e-3)))
back = uf.run(line, b.run_spec(measured_output_pulse, backward=fx.backward("end", "input")))
seed = fx.reconstructed_pulse(back) # a pulse dict for new runsBuilders: transform, spectral_phase, spectral_amplitude, energy, delay, jones, replica, phase_noise,
pedestal, wavefront, fit_value, fit, fit_parameter, backward (all with type hints).
Accessors: fit_report, fitted_system, reconstructed_pulse. Measured data is core: b.measured(...),
res.comparisons, b.axis(...) (instrument sampling) and b.measured_spectrum(...) (Measured data);
fx.measured and fx.comparisons remain as aliases.
- Put each transform where its physics is. Residual dispersion of a stretcher belongs after the stretcher, a gain-narrowing filter after the amplifier. Placed this way the fitted transform still means something when you change the seed or a downstream element.
- Fit levels in dB. Contrast features span decades: use
relativeIntensityDbandlevelDb, and"scale": "log"on the cross-correlator data. - Choose instruments that separate parameters. Look at the correlations and the influence map. A spectrum fixes amplitude but not phase, an autocorrelation cannot tell the sign of the chirp, and a d-scan or FROG can (SHG FROG is symmetric in time: start a phase fit away from zero, where the gradient vanishes).
- Start close, or go global. Levenberg–Marquardt finds the nearest minimum. If you are unsure, run
cmaeswith bounds; it finishes with Levenberg–Marquardt. - Add priors for what the data cannot see, and smoothness for splines. The influence map tells you which parameters rest on priors.
- Model the instrument, including its resolution, sampling and where it looks (
sampling). A fit that compares an on-axis measurement with a whole-beam simulation biases the parameters to explain the difference. - Look at the residuals in
measurements.png. Structure rather than noise means the model misses something, which is often a missing transform operator.
- Fits are static: one set of recordings, fitted once. Live re-fitting as data arrive is planned (see the roadmap).
- Uncertainties from the covariance are linearised; use
mcmcwhen the posterior is not Gaussian. - Backward propagation through amplifiers and crystals is linearised about a reference run. Saturated gain and frequency conversion cannot be undone exactly. Incoherent pedestals cannot be removed, and light the system absorbed completely is not recoverable.
- Wavefront operators change the pulse only when the beam carries a transverse profile (spatial models).
- General low-rank and learned field operators are not built in: add them as your own operator kinds (above).